2008
DOI: 10.1021/jp076920m
|View full text |Cite
|
Sign up to set email alerts
|

Ultrafast Dynamics of the Carbonyl Stretching Vibration in Acetic Acid in Aqueous Solution Studied by Sub-Picosecond Infrared Spectroscopy

Abstract: Vibrational energy relaxation of the carbonyl CO stretching modes of CH3COOD and CD3COOD in D2O is studied by frequency-resolved infrared pump-probe spectroscopy. The spectral change caused by the vibrational excitation includes two dynamical components with the time constants of 450 and 980 fs for CH3COOD and 390 and 930 fs for CD3COOD. The two dynamical components exhibit different spectral properties. There are two species of acetic acid forming different complexes with solvent water molecules. The time con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 26 publications
(27 citation statements)
references
References 41 publications
1
26
0
Order By: Relevance
“…23 Briefly, a mid-IR pulse was generated by difference frequency generation on a AgGaS 2 crystal between the two near-IR outputs, signal and idler pulses of an optical parametric amplifier. A mid-IR pulse has a pulse width of about 100 fs with a repetition rate of 1 kHz, a bandwidth of about 100 cm −1 , and pulse energy of about ∼3 µJ.…”
Section: Methodsmentioning
confidence: 99%
“…23 Briefly, a mid-IR pulse was generated by difference frequency generation on a AgGaS 2 crystal between the two near-IR outputs, signal and idler pulses of an optical parametric amplifier. A mid-IR pulse has a pulse width of about 100 fs with a repetition rate of 1 kHz, a bandwidth of about 100 cm −1 , and pulse energy of about ∼3 µJ.…”
Section: Methodsmentioning
confidence: 99%
“…The details of the apparatus are described elsewhere. 17 Briefly, IR pulses were generated by difference frequency mixing between the signal and the idler pulses from an optical parametric amplifier, pumped by a Ti : sapphire regenerative amplifier. The IR pulse was separated into three pulses: the pump, the probe, and the reference pulses.…”
Section: Methodsmentioning
confidence: 99%
“…The details of the experimental setup for the IR pump-probe and three-pulse IR photon-echo experiments are described elsewhere [3,7,8]. Briefly, a mid-IR pulse was generated by the difference frequency generation on an AgGaS 2 crystal between the two near-IR outputs, signal and idler pulse, of an optical parametric amplifier.…”
Section: Methodsmentioning
confidence: 99%