2018
DOI: 10.1016/j.jelechem.2017.12.010
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-trace determination of silver using lead nanoparticles-modified thiol functionalized polysiloxane film glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(15 citation statements)
references
References 18 publications
1
14
0
Order By: Relevance
“…However, due to the lack of literature addressing this problem, it is difficult to establish a proper comparison. The results of the validation were in agreement with what has been published for methods determining silver in other systems (other working electrodes or modified electrodes) . In this work, Ag + was properly identified and the achievement of a single signal was possible.…”
Section: Discussionsupporting
confidence: 88%
See 2 more Smart Citations
“…However, due to the lack of literature addressing this problem, it is difficult to establish a proper comparison. The results of the validation were in agreement with what has been published for methods determining silver in other systems (other working electrodes or modified electrodes) . In this work, Ag + was properly identified and the achievement of a single signal was possible.…”
Section: Discussionsupporting
confidence: 88%
“…Due to its low toxicity and relatively low cost, carbon has always been an attractive material for electrodes in electroanalysis. Silver has been detected with a wide range of carbon electrodes but only a limited number of articles have been published on the use of glassy carbon electrodes, most of them chemically modified . Numerous articles discuss the determination of silver by electrochemical techniques .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…NMs have been primarily applied on the electrodes in combination with other modifiers (including through the formation of composites). [22][23][24][25]27,[30][31][32]34,46,47,50,54,59,67,70,72,75,83,85,86,88,89,[92][93][94][95][96][97][98][99][100][101][102]107,113,115,117,118,[122][123][124][125][126][129][130][131]135,136,[138][139]...…”
Section: Nanomaterials As Electrode Modifiersmentioning
confidence: 99%
“…The latter's use is restricted due to high mercury toxicity concerns (Lu et al, 2018). In the last years the focus of the research community has been on the modification of the GCE using among others nanomaterials, organic molecules and biomolecules (Bansod et al, 2017;Cui et al, 2015;Lee et al, 2016;Zinoubi et al, 2017;Dahaghin et al, 2018;Sadok and Tyszczuk-Rotko, 2018;Lee et al, 2015;Ariño et al, 2017). Film electrodes, in situ or ex situ prepared with mainly bismuth, but also of copper, lead and tin, have been also explored (Ariño et al, 2017;Jovanovski et al, 2015Jovanovski et al, , 2017Economou, 2005;Petovar et al, 2018;Czop, 2011;Korolczuk et al, 2005).…”
Section: Introductionmentioning
confidence: 99%