2010
DOI: 10.1016/j.aca.2010.05.012
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
2
2

Relationship

2
8

Authors

Journals

citations
Cited by 59 publications
(29 citation statements)
references
References 52 publications
0
28
0
Order By: Relevance
“…The most significant interferences for Pu measurements by ICP-MS are the formation of isobaric uranium hydrides ( 238 UH + ) and peak tailing from the 238 U + peak, which may cause overestimation of the 239 Pu signal. The analytical procedure for the determination of Pu in coral samples is based on a previously reported method (Lindahl et al, 2010a). Briefly, the powder samples were first dried for 24 h at 80°C and spiked with 242 Pu (0.4 mBq) as a yield monitor.…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…The most significant interferences for Pu measurements by ICP-MS are the formation of isobaric uranium hydrides ( 238 UH + ) and peak tailing from the 238 U + peak, which may cause overestimation of the 239 Pu signal. The analytical procedure for the determination of Pu in coral samples is based on a previously reported method (Lindahl et al, 2010a). Briefly, the powder samples were first dried for 24 h at 80°C and spiked with 242 Pu (0.4 mBq) as a yield monitor.…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…In literature, various procedures for the separation of actinides with TRU ® resin are presented 26 , 27 , 29 , 31 , 33 , 34 . Although 5 to 10 mL of 4 M HNO 3 is commonly used for equilibration of the resin and rinsing/washing after the sample loading, various separation procedures of Pu and Am were examined to obtain better chemical yield using radioactive tracers ( 242 Pu IRMM-085 and 243 Am NIST 4332E) and liquid scintillation counting.…”
Section: Sampling and Experimental Methodsmentioning
confidence: 99%
“…Inductively coupled plasma mass spectrometry (ICP-MS) is undoubtedly one of the fastestgrowing tracer element techniques available today, which has clear advantages in its multiisotope capability, high speed of analysis and low detection limits [29][30][31][32][33]. With the implementation of ICP-MS instruments, more and more researchers have reported the use of ICP-MS for the determination of 238 U in seawater [34][35][36][37][38][39][40].…”
Section: Introductionmentioning
confidence: 99%