2009
DOI: 10.1016/j.cplett.2009.10.067
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-sensitive optical measurements of high-J transitions in the O2 A-band

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
19
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 47 publications
1
19
0
Order By: Relevance
“…All measurements were made over the temperature range 297.7-299.4 K. The combined standard uncertainty in the cell temperature has recently been shown to be ∼30 mK. 40 Measured air-broadening parameters were temperature corrected to T ref = 296 K using the temperature dependences found in the HITRAN 2008 database. 51 As these measurements were made near the reference temperature, temperature corrections to the air-broadening parameters were small.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…All measurements were made over the temperature range 297.7-299.4 K. The combined standard uncertainty in the cell temperature has recently been shown to be ∼30 mK. 40 Measured air-broadening parameters were temperature corrected to T ref = 296 K using the temperature dependences found in the HITRAN 2008 database. 51 As these measurements were made near the reference temperature, temperature corrections to the air-broadening parameters were small.…”
Section: Methodsmentioning
confidence: 99%
“…In addition, FS-CRDS is a single-mode technique that enables the accurate measurement of sample absorption coefficient in terms of observed ring-down cavity decay time constants. FS-CRDS has been employed to measure ultra-weak transitions, 39,40 hyperfine structure 37 and rare isotopes, 42,43,49 and to produce reference standard spectroscopic data. 36,38,42,43,50 For the measurements described herein the probe laser was an external cavity diode laser with an output power of ∼15 mW and the reference laser was a frequency-stabilized HeNe laser with a long-term stability of 1 MHz (8 h).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A The combined uncertainty (random and systematic) of this temperature measurement is ∼28 mK [14]. Spectra were fit using Voigt line-shape profiles, which account for pressure (Lorentzian) and Doppler (Gaussian) broadening.…”
mentioning
confidence: 99%
“…A continuous spectrum was measured over the R branch of the b 1 + g ← X 3 − g (0,0) band (13126-13165 cm −1 ) with a step size of 100 MHz (∼0.003 cm −1 ). Sub-FSR frequency steps were enabled by frequency shifting the HeNe reference laser through the use of an acousto-optic modulator in a double-pass configuration [10].A The combined uncertainty (random and systematic) of this temperature measurement is ∼28 mK [14]. Spectra were fit using Voigt line-shape profiles, which account for pressure (Lorentzian) and Doppler (Gaussian) broadening.…”
mentioning
confidence: 99%