2016 IEEE International Conference on Advances in Electronics, Communication and Computer Technology (ICAECCT) 2016
DOI: 10.1109/icaecct.2016.7942575
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-low power comb filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 10 publications
0
8
0
Order By: Relevance
“…Analog filters hold a distinct advantage for real-time signal processing compared to digital counterparts. Consequently, numerous analog comb filters have been listed in existing literature [3] , [4] , [5] , [6] , [7] , [8] , [9] to eliminate the primary frequency of PLI and its associated odd harmonics from biological signals like electrocardiogram (ECG), electroencephalogram (EEG), and electromyogram (EMG).…”
Section: Methods Detailsmentioning
confidence: 99%
See 3 more Smart Citations
“…Analog filters hold a distinct advantage for real-time signal processing compared to digital counterparts. Consequently, numerous analog comb filters have been listed in existing literature [3] , [4] , [5] , [6] , [7] , [8] , [9] to eliminate the primary frequency of PLI and its associated odd harmonics from biological signals like electrocardiogram (ECG), electroencephalogram (EEG), and electromyogram (EMG).…”
Section: Methods Detailsmentioning
confidence: 99%
“…The key benefits of the suggested comb filter, which represents the novelty of the circuit by overcoming the literature research gaps, can be summarized as follows: Minimal Active Building Blocks: The proposed comb filter is notably efficient regarding active components, requiring only 4 VDCCs. Meanwhile, in [3] , [4] , [5] , [6] , [7] , [8] , more than four active building blocks are used. Reduced Passive Components: Besides its frugality with active components, the proposed filter employs fewer passive components than [3] , [4] , [5] , [6] , [7] , [8] .…”
Section: Methods Detailsmentioning
confidence: 99%
See 2 more Smart Citations
“…To suppress or attenuate the 50Hz or 60Hz PLI, a variety of analog notch filters designed with distinct active blocks have been proposed by several researchers, aimed at processing different types of biomedical signals. These circuits, which employ current-mode active blocks such as the secondgeneration current conveyor (CCII) [15][16][17], differential difference current conveyor (DDCC) [18], and differential voltage current conveyor (DVCC) [19], hold distinct advantages, including a larger dynamic range, simpler circuit architecture, and lower power consumption.…”
Section: Figure 2 Block Diagram Of the Biosignal Detection Systemmentioning
confidence: 99%