2017
DOI: 10.1038/srep41100
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-high resolution profiles of macular intra-retinal layer thicknesses and associations with visual field defects in primary open angle glaucoma

Abstract: The structural characteristics of the outer retinal layers in primary open angle glaucoma (POAG) are still controversial, and these changes, along with those in the inner retinal layers, could have clinical and/or pathophysiological significance. A custom-built ultra-high resolution optical coherence tomography (UHR-OCT) combined with an automated segmentation algorithm can image and measure the eight intra-retinal layers. The purpose of this study is to determine the thickness characteristics of the macular i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
18
0
2

Year Published

2017
2017
2020
2020

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 25 publications
(22 citation statements)
references
References 22 publications
1
18
0
2
Order By: Relevance
“…As described previously, 16,22 each cross-sectional image that included the retina and choroid was analyzed by one masked reader (YW) to segment the 10 boundaries of the intraretinal layers and the choroidal layer. The segmentation was achieved by a dedicated software program based on the gradient information and shortest path search that was developed in Matlab (The MathWorks, Inc., Natick, MA, USA) for automated image analysis.…”
Section: Oct Procedures and Data Collectionmentioning
confidence: 99%
“…As described previously, 16,22 each cross-sectional image that included the retina and choroid was analyzed by one masked reader (YW) to segment the 10 boundaries of the intraretinal layers and the choroidal layer. The segmentation was achieved by a dedicated software program based on the gradient information and shortest path search that was developed in Matlab (The MathWorks, Inc., Natick, MA, USA) for automated image analysis.…”
Section: Oct Procedures and Data Collectionmentioning
confidence: 99%
“…As described previously [16,23], the magnification of each cross-sectional retinal image was adjusted by the axial length and was then analyzed by one masked reader (YW) to segment the nine boundaries of the intra-retinal layers (Fig. 2a).…”
Section: Quantitative Analysis Of Oct Images Based On Retinal Thicknessmentioning
confidence: 99%
“…3]. The slab thickness was fixed for all subjects as in Refs [18,32] and was slightly thinner than the value previously reported for the EZ thickness of a population of healthy subjects [33], in order to minimize the effect of outliers. Fig.…”
Section: Identification Of Ez Boundary Location and Generation Of En mentioning