1957
DOI: 10.1007/bf01837580
|View full text |Cite
|
Sign up to set email alerts
|

Über die papierchromatographische Bestimmung der in Fleischprodukten verwendeten PhosphateI. Mitteilung Der qualitative Nachweis der Ortho-, Pyro- und Polyphosphate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0
1

Year Published

1959
1959
2019
2019

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 0 publications
0
12
0
1
Order By: Relevance
“…Assessment of water holding capacity was performed applying the method according to Grau and Hamm (1952) in Pohja and Niinivaara's (1957) modification. A sample of comminuted meat of 300 g mass was placed on blotting paper of Whatman 1 type, next it was situated between two glass plates and subjected to an even load of 2 kg for 5 min.…”
Section: Methodsmentioning
confidence: 99%
“…Assessment of water holding capacity was performed applying the method according to Grau and Hamm (1952) in Pohja and Niinivaara's (1957) modification. A sample of comminuted meat of 300 g mass was placed on blotting paper of Whatman 1 type, next it was situated between two glass plates and subjected to an even load of 2 kg for 5 min.…”
Section: Methodsmentioning
confidence: 99%
“…Assessment of water holding capacity was determined by the method of Grau and Hamm (1952), modified by Pohja and Niinivaara (1957). A sample of 300 mg finely ground meat was applied to Whatman 1 paper, placed between two glass plates and subjected to an even loading of 2 kg for 5 min.…”
Section: Methodsmentioning
confidence: 99%
“…During cutting, meat samples were collected from the LD muscle from the lumbar vertebrae 1 to 4 section of the right half-carcass. Approximately 48 h after slaughter, pH measurement was done in a water solution on mixed and diluted muscle tissue, meat colour lightness (L*) was determined by means of HunterLab Mini Scan XE 45/0 apparatus (CIE, 1976), water-holding capacity was determined by the Grau and Hamm (1952) method as modified by Pohja and Niinivaara (1957), thermal drip from a difference in meat sample weight before and after heating in water bath at 85°C for 10 min, watersoluble protein content by the Kotik (1974) method, as well as the assay of meat basic chemical composition, i.e. total protein, fat, ash, and dry matter (AOAC, 2003), was carried out.…”
Section: Methodsmentioning
confidence: 99%