1990
DOI: 10.1097/00005131-199004020-00002
|View full text |Cite
|
Sign up to set email alerts
|

Type II Distal Clavicle Fractures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
12
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 144 publications
(15 citation statements)
references
References 0 publications
0
12
0
Order By: Relevance
“…Kona et al [17] reported an unacceptably high complication rate (47%) with the use of K-wires and advised against its use. Flinkkila et al [1] compared K-wire fixation to hook plate fixation.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Kona et al [17] reported an unacceptably high complication rate (47%) with the use of K-wires and advised against its use. Flinkkila et al [1] compared K-wire fixation to hook plate fixation.…”
Section: Discussionmentioning
confidence: 99%
“…The indirect reduction method requires extensive dissection around the fracture and bore holes through the clavicle and the coracoid process. Erosion of these structures and fracture of the clavicle and the coracoid are well recognized complications [17,23,24]. Especially in case of the rigid fixation with the Bosworth screw, and in lesser extent with the other devices, the rotation of the clavicle is disabled requiring partial immobilization of the shoulder until fracture consolidation with the potential of implant breakage and a longer revalidation period.…”
Section: Discussionmentioning
confidence: 99%
“…K-wires with cerclage have a high rate of infection and nonunion due to migration of the K-wires [5]. …”
Section: Discussionmentioning
confidence: 99%
“…Since Neer [3, 4] first described fixing these fractures with two transarticular K-wires, many techniques and methods have been described for fixation. This indirectly suggests that these methods do not always yield the desired results [5]. In the last decade, the hook plate—originally developed by Balser to treat acromioclavicular dislocations—has been used as treatment for this difficult fracture [6].…”
Section: Introductionmentioning
confidence: 99%
“…21 K-wire fixation have high complication rate like pin migration and superficial pin tract infection. 22,15 In the study done by Lee et al, they compared the tension band wiring with hook plate fixation and they found early return to daily activities can be achieved by hook plate fixation. In their study they had 30% complications in tension band wiring fixation group.…”
mentioning
confidence: 99%