2003
DOI: 10.4028/www.scientific.net/ssp.92.165
|View full text |Cite
|
Sign up to set email alerts
|

TXRF Analysis of Low Z Elements and TXRF-NEXAFS Speciation of Organic Contaminants on Silicon Wafer Surfaces Excited by Monochromatized Undulator Radiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
6
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Furthermore, calibrated detectors have been used, enabling reference-free quantitation of contamination. The present paper addresses the following topics: a detailed description of the dedicated TXRF instrumentation built by PTB, detection sensitivities achieved so far by PTB and various cooperation partners at the electron storage ring BESSY II, the systematic optimization of detection limits of selected elements such as Al, the speciation of contamination, and recent developments in reference-free quantitation in TXRF analysis including its error budget as well as perspectives of this quantitation mode in table-top instruments.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore, calibrated detectors have been used, enabling reference-free quantitation of contamination. The present paper addresses the following topics: a detailed description of the dedicated TXRF instrumentation built by PTB, detection sensitivities achieved so far by PTB and various cooperation partners at the electron storage ring BESSY II, the systematic optimization of detection limits of selected elements such as Al, the speciation of contamination, and recent developments in reference-free quantitation in TXRF analysis including its error budget as well as perspectives of this quantitation mode in table-top instruments.…”
mentioning
confidence: 99%
“…Reference-free quantitation in TXRF analysis requires specially designed instrumentation involving high standards in wafer positioning as well as very well-known X-ray excitation and detection characteristics. For the purpose of semiconductor surface analysis, PTB built XRF and TXRF instrumentation that can handle 15−75 mm as well as 200- and 300-mm silicon wafers. The TXRF and XRF instrumentation, which is suitable for handling 15−75-mm Si or SiC wafers, is described elsewhere. , This instrumentation is located in the focal plane of the PTB's plane grating monochromator (PGM) beamline , for undulator radiation within the PTB laboratory at BESSY II and, additionally, can be positioned below a local minienvironment to avoid unintentional cross-contamination of the wafer samples.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The whole wafer surface of a 200 and a 300 mm wafer can be scanned. 40 Recent activites report on detection limits below 100 fg for Al and below 40 fg for Na. Also reference free quantification was performed successfully.…”
Section: Recent Activitiesmentioning
confidence: 99%
“…For analytical investigations relevant for the semiconductor industry, the PTB can handle 200 mm and 300 mm silicon wafers as well as smaller semiconductor wafers in its TXRF, GIXRF and XRF instrumentation (1,2). To prevent undesired cross-contamination of the wafers, the instrumentations are protected by mobile cleanrooms (cfr.…”
Section: Semiconductor Characterization By Reference-free X-ray Spect...mentioning
confidence: 99%