2012
DOI: 10.1016/j.resp.2012.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Two weeks of buspirone protects against posthypoxic ventilatory pauses in the C57BL/6J mouse strain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 19 publications
(17 citation statements)
references
References 15 publications
1
16
0
Order By: Relevance
“…C57BL6 mice have been used extensively to study the effects of HX, HC and H-H gas challenges on ventilatory function (see Palmer et al, 2013a,b, 2014; Gaston et al, 2014) and disordered breathing (Han et al, 2001, 2002; Tagaito et al, 2001; Schneider et al, 2003; Yamauchi et al, 2007, 2008a, 2012; Moore et al, 2012, 2014). Although Swiss-Webster mice have been used in studies concerned with the effects of 2 min episodes of HX and HC challenges on ventilatory parameters (Schenkler et al, 2002) and the effects of 5 min episodes of hypoxia-induced gasping (Jacobi and Thach, 1989), no studies have addressed the relationships between ventilatory performance and level of disordered breathing at rest, during HX or HC challenges, and upon return to room-air.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…C57BL6 mice have been used extensively to study the effects of HX, HC and H-H gas challenges on ventilatory function (see Palmer et al, 2013a,b, 2014; Gaston et al, 2014) and disordered breathing (Han et al, 2001, 2002; Tagaito et al, 2001; Schneider et al, 2003; Yamauchi et al, 2007, 2008a, 2012; Moore et al, 2012, 2014). Although Swiss-Webster mice have been used in studies concerned with the effects of 2 min episodes of HX and HC challenges on ventilatory parameters (Schenkler et al, 2002) and the effects of 5 min episodes of hypoxia-induced gasping (Jacobi and Thach, 1989), no studies have addressed the relationships between ventilatory performance and level of disordered breathing at rest, during HX or HC challenges, and upon return to room-air.…”
Section: Discussionmentioning
confidence: 99%
“…The genetic bases for sleep disordered breathing in mouse strains have received extensive investigation (Tankersley et al, 1994, 1998, 2000, Tankersley, 2000, 2001, 2003; Han and Strohl, 2000; Han et al, 2001, 2002; Tagaito et al, 2001; Schneider et al, 2003; Strohl, 2003; Tankersley and Broman, 2004; Balbir et al, 2006; Yamauchi et al, 2008b; Gillombardo et al, 2012) as have the neurochemical processes (Tankersley et al, 2002b; Price et al, 2003; Groeben et al, 2005; Yamauchi et al, 2007, 2008a, 2012; Moore et al, 2012, 2014), and structural features of respiratory structures such as the carotid bodies (Yamaguchi et al, 2003, 2006; Chai et al, 2011). …”
Section: Introductionmentioning
confidence: 99%
“…Variations of pressure in the chamber are recorded as voltage swings by the transducer output, and were entered for data analyses using Lab View 7.1 (National Instruments, Austin, TX ). The output was analyzed and scored using a customized program (Breath Detect using LabView programming by Innovative Computer Engineering, Cleveland, OH)(Moore et al, 2012). The program identifies an individual breath according to the crest and trough of the transducer’s voltage output, but the investigator visually verifies the result.…”
Section: Methodsmentioning
confidence: 99%
“…However, intracerebroventricular antagonism of α 2 -adrenoreceptors does not prevent STD (53), suggesting that α 2 -adrenoreceptors are not required but rather modulate the response (13). Serotonin (5-HT), also appears to be involved in STD since antagonism of 5-HT 2A/C receptors augments STD in rats (188), and antagonism of 5-HT 1A receptors is required to reveal the occurrence of STD in mice (267) (Fig. 4).…”
Section: Physiological and Molecular Responses To Brief Hypoxic Exposmentioning
confidence: 99%
“…However, researchers have since identified this mechanism in conscious rats and mice (55, 267) and also in awake humans (377). Additionally, this time domain of the HVR is sensitive to genetic differences, as indicated by the observation that the magnitude of STD can differ between strains of rats and also within substrains (144, 215, 379).…”
Section: Physiological and Molecular Responses To Brief Hypoxic Exposmentioning
confidence: 99%