Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2022
DOI: 10.3390/bios12110981
|View full text |Cite
|
Sign up to set email alerts
|

Two-Way Detection of COVID-19 Spike Protein and Antibody Using All-Dielectric Metasurface Fluorescence Sensors

Abstract: COVID-19 (or SARS-CoV-2) has deeply affected human beings worldwide for over two years, and its flexible mutations indicate the unlikeliness of its termination in a short time. Therefore, it is important to develop a quantitative platform for direct COVID-19 detection and human status monitoring. Such a platform should be simpler than nucleic acid amplification techniques such as polymerase chain reaction, and more reliable than the disposable test kits that are based on immunochromatography. To fulfill these … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 34 publications
0
12
0
Order By: Relevance
“…In the semi-log plots, it is difficult to see the changes in FL intensity at low concentrations below 1 ng/mL; however, the linear plots in the insets exhibit the scaled responses of the metasurface biosensors, even at the range that is 25-fold smaller than the clinical criterion. We refer to that of the dynamic range, which is mainly limited by the performance of the uncooled CCD camera; indeed, a confocal FL microscopy enabled us to access much lower concentrations when we detected the spike proteins of SARS-CoV-2 [ 21 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In the semi-log plots, it is difficult to see the changes in FL intensity at low concentrations below 1 ng/mL; however, the linear plots in the insets exhibit the scaled responses of the metasurface biosensors, even at the range that is 25-fold smaller than the clinical criterion. We refer to that of the dynamic range, which is mainly limited by the performance of the uncooled CCD camera; indeed, a confocal FL microscopy enabled us to access much lower concentrations when we detected the spike proteins of SARS-CoV-2 [ 21 ].…”
Section: Resultsmentioning
confidence: 99%
“…Unbound CEA-sandwich bodies were rinsed with the PBS-T. Afterwards, the FL imaging was conducted from the top of metasurface biosensor; the optical configuration of the biosensor has been described in previous publications [ 20 , 21 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…34 Furthermore, robust detections of CEA and PSA in human serums were recently shown. 33 Thus, it is expected that the metasurface FL biosensors can significantly reinforce the efficiency of FL detection when they are combined with other biosensing techniques, such as ordinary PCR. However, it has not yet been examined whether the metasurface biosensors are capable of detecting a single target molecule.…”
mentioning
confidence: 99%