2023
DOI: 10.1016/j.jmmm.2022.170170
|View full text |Cite
|
Sign up to set email alerts
|

Two-voxel-analysis to assess the spatial resolution of a tracer in Lissajous-scanning magnetic particle imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…To assess the spatial resolution of the three MNP systems SynP50, SynC30, and RES in cells, we conducted the two-voxel analysis as described previously 44 . Instead of using a reference sample prepared directly from MNP stock suspension, 5·10 6 MNP-loaded cells were used for SF acquisition.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To assess the spatial resolution of the three MNP systems SynP50, SynC30, and RES in cells, we conducted the two-voxel analysis as described previously 44 . Instead of using a reference sample prepared directly from MNP stock suspension, 5·10 6 MNP-loaded cells were used for SF acquisition.…”
Section: Resultsmentioning
confidence: 99%
“…Figure 3 illustrates the separation quality Q s as a function of distance x (number of empty voxels) as obtained by the two-voxel analyzes for samples containing MNP-loaded cells from which the MPI resolution r is extracted 44 . The resolution r is defined as the voxel distance x at which Q s is 50%.…”
Section: Resultsmentioning
confidence: 99%
“…The two-voxel-analysis is an efficient procedure to determine the achievable resolution in MPI directly from a SF measurement to synthetically construct MPI measurements of two point-like tracer samples at varying distances. 20 To simulate an array of two different tracers sources, the corresponding data are extracted from the SF and superimposed, with the additional inclusion of noise data from an empty scanner measurement, giving the total complex voltage signal ū . We only used frequency components of the SF above a certain signal-to-noise (SNR > 4) level, otherwise the reconstruction of the tracer distribution would be based on the noise of the SF acquisition.…”
Section: Methodsmentioning
confidence: 99%
“…The result is normalized to the iron content of the voxel. 20 The image resolution r is then determined by the distance at which the minimum has decreased to 50% of the maximum tracer content. To compare the resolution of different tracer systems, we used a spiral resolution phantom as introduced in ref.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation