1961
DOI: 10.1115/1.3683677
|View full text |Cite
|
Sign up to set email alerts
|

Two-Phase Frictional Pressure Drop Prediction From Levy’s Momentum Model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1964
1964
2017
2017

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…. Figure 6.8 Comparison between experimental results obtained in Kanizawa & Ribatski (2017b) and the two-phase pressure drop ∆P 2φ estimated according to Kanizawa & Ribatski (2017b), Marchaterre (1961) .12 Damping factors analysis for results entitled as .13 Experimental damping measurements compiled in Pettigrew & Taylor (2004) for Freon 22 (T 30 ¥ C) compared to the transverse damping model proposed by Sim & Mureithi (2014) .14 Experimental damping measurements compiled in Pettigrew & Taylor (2004) for Freon 11 (T 36 ¥ C) compared to the transverse damping model proposed by Sim & Mureithi (2014) .18 Transition curves for air-water two-phase flow (P 95kP a; T 25 ¥ C) according to Kanizawa & Ribatski (2016a). Pentagram marks correspond to half the mass flux for fluidelastic instability threshold and circle filled marks correspond to transition zone.…”
Section: Introductionmentioning
confidence: 90%
See 3 more Smart Citations
“…. Figure 6.8 Comparison between experimental results obtained in Kanizawa & Ribatski (2017b) and the two-phase pressure drop ∆P 2φ estimated according to Kanizawa & Ribatski (2017b), Marchaterre (1961) .12 Damping factors analysis for results entitled as .13 Experimental damping measurements compiled in Pettigrew & Taylor (2004) for Freon 22 (T 30 ¥ C) compared to the transverse damping model proposed by Sim & Mureithi (2014) .14 Experimental damping measurements compiled in Pettigrew & Taylor (2004) for Freon 11 (T 36 ¥ C) compared to the transverse damping model proposed by Sim & Mureithi (2014) .18 Transition curves for air-water two-phase flow (P 95kP a; T 25 ¥ C) according to Kanizawa & Ribatski (2016a). Pentagram marks correspond to half the mass flux for fluidelastic instability threshold and circle filled marks correspond to transition zone.…”
Section: Introductionmentioning
confidence: 90%
“…It is worth mentioning that the mass velocity, G, for the estimation of u g and u l is based on the minimum cross sectional area. According to Sim & Mureithi (2014), better damping estimations for two-phase air-water systems (low pressure systems) are calculated by using the two-phase friction multiplier, φ 2 L0 (L0 stands for the two-phase mixture flowing as liquid), defined in Marchaterre (1961) apud (SIM; MUREITHI, 2014) as follows:…”
Section: Design Guidelines For Damping In Two-phase Flowmentioning
confidence: 99%
See 2 more Smart Citations