2014
DOI: 10.1016/j.pnucene.2014.06.006
|View full text |Cite
|
Sign up to set email alerts
|

Two-phase flow measurements at high void fraction by a Venturi meter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(7 citation statements)
references
References 7 publications
1
6
0
Order By: Relevance
“…This leads to a high value of the venturi discharge coefficient, much larger than that of the orifice meter discharge coefficient, which usually falls between 0.58 and 0.65. Both the tendency of the curve and the final stable value agree well with Monni et al’s report to some degree.…”
Section: Resultssupporting
confidence: 91%
See 1 more Smart Citation
“…This leads to a high value of the venturi discharge coefficient, much larger than that of the orifice meter discharge coefficient, which usually falls between 0.58 and 0.65. Both the tendency of the curve and the final stable value agree well with Monni et al’s report to some degree.…”
Section: Resultssupporting
confidence: 91%
“…For a given venturi, the throat diameter ratio is fixed (β = 0.4 in this work) and only the effect of the Reynolds number needs to be considered. As reported by Monni et al, the dependence of the discharge coefficient on the Reynolds number can be approximated by an exponential law of the type with coefficients a and b obtained from the experimental data: …”
Section: Model Developmentmentioning
confidence: 95%
“…Measurements of pressure drops of a vertical upward annular air–water flow between the inlet and throat and between inlet and outlet sections of a Venturi have been performed by Monni et al. 8 They derived a relationship between the pressure drops and the phase superficial velocities as well as the mass flow rate of the mixture. They reported that the quality was estimated with an accuracy of 5%, while those of the gas and liquid mass flow rates can be evaluated with accuracies better than 2 and 30%, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…The latter shows a more significant effect on the flow through Venturi than it is in the straight pipe. Monni et al 17 analysed experimentally the irreversible pressure drop along the distance from the inlet to the throat and from the inlet to the outlet section of the Venturi for vertical annular (wet gas) two-phase flow with a void fraction higher than 97%. They used the quick closing valve for the volumetric void fraction measurement.…”
Section: Introductionmentioning
confidence: 99%