2016
DOI: 10.1016/j.molliq.2015.12.011
|View full text |Cite
|
Sign up to set email alerts
|

Two-length scale description of hydrophobic room-temperature ionic liquid–alcohol systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 23 publications
(19 citation statements)
references
References 30 publications
0
19
0
Order By: Relevance
“…As additive effect, isomer effects of alcohols in the RTILs were observed distinctly [14]- [17]. A previous study estimated the molecular interactions between RTILs and propanol on desorption time measured under vacuum [14].…”
Section: Introductionmentioning
confidence: 90%
See 2 more Smart Citations
“…As additive effect, isomer effects of alcohols in the RTILs were observed distinctly [14]- [17]. A previous study estimated the molecular interactions between RTILs and propanol on desorption time measured under vacuum [14].…”
Section: Introductionmentioning
confidence: 90%
“…In [N4111][TFSI]-propanol system, however, there is a problem of phase separation in the propanol-rich region. [TFSI]-propanol system was constructed based on visual cloud-point determinations [14] [15] [17]. The cloud-points of 1-and 2-based mixtures are represented by red and blue closed circles, respectively.…”
Section: Thermal Properties Of Nco 2 Capturementioning
confidence: 99%
See 1 more Smart Citation
“…In order to distinguish between amorphous ice and crystal ice in the water pocket inside [C 4 mim][NO 3 ], we carried out in situ observations using simultaneous X‐ray diffraction and DSC (SmartLab, Rigaku Co.) . In the simultaneous measurements, ranges of temperature and cooling/heating rate are −100 to 350 °C and 0.5 to 10 °C min −1 , respectively.…”
Section: Methodsmentioning
confidence: 99%
“…In order to distinguish between amorphous ice and crystal ice in the water pocket inside [C 4 mim][NO 3 ], we carried out in situ observations using simultaneous X-ray diffraction and DSC (SmartLab, Rigaku Co.). [27] In the simultaneous measurements, ranges of temperature and cooling/heating rate are À100 to 350 8Ca nd 0.5 to 10 8Cmin À1 ,r espectively.F or liquid samples, it is essential that the sample stage on av ertical goniometer is maintained horizontal. The DSC is attached onto the goniometer.D ry nitrogen gas flowed inside the DSC at 20 cc min À1 .F or the simultaneous measurements, Cu K a radiation (l = 1.542 ) was selected.…”
Section: Methodsmentioning
confidence: 99%