Two-Dimensional Echocardio-graphic Evaluation of Left Ventricular Ejection Fraction by the Ellipsoid Single-Plane Algorithm: A Reliable Method for Assessing Low or Very Low Ejection Fraction Values?

Abstract: The reliability of two-dimensional (2D) echocardiographic estimation of left ventricular ejection fraction (EF) is commonly recognized, but no satisfactory data are available about the accuracy of low or very low EF values determined by 2D echocardiography (ECHO-EF). The purpose of our study was to assess the reliability of low ECHO-EF values obtained using a simple time-economical algorithm such as the ellipsoid single-plane area-length method. Radionuclide angiography (RAD-EF) was taken as the standard of co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1998
1998
2017
2017

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Furthermore, both models include LV ejection fraction as a covariable, but the calculation of an exact LV ejection fraction by echocardiogram in HF patients can sometimes be challenging especially in patients with geometric abnormality or segmental asynergy. 25,26 We believe that the risk stratification model based on only a few objective variables would clinically be useful. The measurement of BNP is a simple and easily obtainable method in the clinical setting.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, both models include LV ejection fraction as a covariable, but the calculation of an exact LV ejection fraction by echocardiogram in HF patients can sometimes be challenging especially in patients with geometric abnormality or segmental asynergy. 25,26 We believe that the risk stratification model based on only a few objective variables would clinically be useful. The measurement of BNP is a simple and easily obtainable method in the clinical setting.…”
Section: Discussionmentioning
confidence: 99%
“…All the measurements of cavities and wall thickness were made by the leading-edge method (http://www.ncbi.nlm.nih.gov/pubmed/2698218) and averaged over three cardiac cycles. The ejection fraction (EF) was calculated by using the area-length formula as previously described [19]. We computed LV mass in grams using the following formula: 0.8×(1.04[(LVID + IVS + PWT)3− LVID3]) +0.6 [20].…”
Section: Methodsmentioning
confidence: 99%
“…[5, 6] Moreover, even though the echocardiographic estimation of LVEF is commonly trusted, few accuracy data are available for subjects with depressed LV systolic function. [7]…”
Section: Introductionmentioning
confidence: 99%