2015
DOI: 10.1364/ao.54.008644
|View full text |Cite
|
Sign up to set email alerts
|

Two-channel algorithm for single-shot, high-resolution measurement of optical wavefronts using two image sensors

Abstract: We propose a two-channel holographic diversity interferometer (2ch-HDI) system for single-shot and highly accurate measurements of complex amplitude fields with a simple optical setup. In this method, two phase-shifted interference patterns are generated, without requiring a phase-shifting device, by entering a circularly polarized reference beam into a polarizing beam splitter, and the resulting patterns are captured simultaneously using two image sensors. However, differences in the intensity distributions o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 23 publications
0
9
0
Order By: Relevance
“…In case that the piezoelectric device is not able to work properly inside a turbulent environment, the setup mentioned in Fig. 1 can be extended with the Two-Frame-Phaseshifting-method [5] to capture two phase-shifted holograms using two CCDs at the same time.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In case that the piezoelectric device is not able to work properly inside a turbulent environment, the setup mentioned in Fig. 1 can be extended with the Two-Frame-Phaseshifting-method [5] to capture two phase-shifted holograms using two CCDs at the same time.…”
Section: Methodsmentioning
confidence: 99%
“…Thus DHM qualifies well for the fast and precise inspection of the inner of micro parts. Additionally DHM was shown to be used in a single exposure recording with the help of Two-Frame-Phase Shifting [5], making DHM very robust and applicable in a production line. A major problem for DHM is the occurrence of ambiguities when the roughness of the observed object is greater than half of the used wavelength.…”
Section: Introductionmentioning
confidence: 99%
“…Then, the SCM image was displayed onto the PSLM. After that, the complex amplitude distribution of the reconstructed light was measured by holographic diversity interferometry (HDI) 13,14 , which is one of the phase-shifting digital holography. Figure 6 shows the experimental results.…”
Section: Methodsmentioning
confidence: 99%
“…This is accomplished by using circular polarized light from the object and linear polarized light from the reference mirror. Nozawa et al have already used this system for single-shot and highly accurate measurements of complex amplitude fields with a simple optical setup [Noz15].…”
Section: Two-frame Phase-shiftingmentioning
confidence: 99%