2009
DOI: 10.1021/jp907393m
|View full text |Cite
|
Sign up to set email alerts
|

Two Bathointermediates of the Bacteriorhodopsin Photocycle, from Time-Resolved Nanosecond Spectra in the Visible

Abstract: Time-resolved measurements were performed on wild-type bacteriorhodopsin with an optical multi-channel analyzer in the spectral range of 350–735 nm, from 100 ns to the photocycle completion, at four temperatures in the 5–30 °C range. The intent was to examine the possibility of two K-like bathochromic intermediates and to obtain their spectra and kinetics in the visible. The existence of a second K-like intermediate, termed KL, had been postulated (Shichida et al., BBA 723:240–246, 1983) to reconcile inconsist… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
18
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(20 citation statements)
references
References 85 publications
2
18
0
Order By: Relevance
“…To obtain time-resolved spectra of intermediates, single-wavelength kinetic traces were collected separately at 18 wavelengths covering the 380–720 nm region with steps of 20 nm, and subjected to analysis using the FitExp and Schemefit programs 56 . At first global (multi-exponential) fitting was performed with FitExp program, and the minimal sufficient number of exponential components was evaluated by F-test statistics and analysis of residuals, see 56 for details.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…To obtain time-resolved spectra of intermediates, single-wavelength kinetic traces were collected separately at 18 wavelengths covering the 380–720 nm region with steps of 20 nm, and subjected to analysis using the FitExp and Schemefit programs 56 . At first global (multi-exponential) fitting was performed with FitExp program, and the minimal sufficient number of exponential components was evaluated by F-test statistics and analysis of residuals, see 56 for details.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…At first global (multi-exponential) fitting was performed with FitExp program, and the minimal sufficient number of exponential components was evaluated by F-test statistics and analysis of residuals, see 56 for details. This number is equal to the number of distinct intermediates detected experimentally 56 .…”
Section: Experimental Methodsmentioning
confidence: 99%
See 3 more Smart Citations