2003
DOI: 10.1016/s1352-2310(03)00004-9
|View full text |Cite
|
Sign up to set email alerts
|

Tunable diode laser absorption spectrometer measurements of ambient nitrogen dioxide, nitric acid, formaldehyde, and hydrogen peroxide in Parlier, California

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 33 publications
0
11
0
Order By: Relevance
“…The advantages of in situ spectroscopic methods are their compound specificity and high time resolution. A number of techniques have been reported for formaldehyde measurements including tunable diode laser spectroscopy (TDLAS) [14,15], differential optical absorption spectroscopy (DOAS) [16,17], Fourier transform infrared spectroscopy (FT-IR) [18] and remote spectroscopic methods using satellite based sensors [19][20][21]. Other specific techniques for formaldehyde are laser induced fluorescence [22], fluorimetric methods based on the Hantzsch reaction [23,24] and an enzymatic method [25].…”
Section: Introductionmentioning
confidence: 99%
“…The advantages of in situ spectroscopic methods are their compound specificity and high time resolution. A number of techniques have been reported for formaldehyde measurements including tunable diode laser spectroscopy (TDLAS) [14,15], differential optical absorption spectroscopy (DOAS) [16,17], Fourier transform infrared spectroscopy (FT-IR) [18] and remote spectroscopic methods using satellite based sensors [19][20][21]. Other specific techniques for formaldehyde are laser induced fluorescence [22], fluorimetric methods based on the Hantzsch reaction [23,24] and an enzymatic method [25].…”
Section: Introductionmentioning
confidence: 99%
“…The other continuous analyzer was completely fulfilled in IRCELYON laboratory. It is based on formaldehyde trapping in a 3-methylbenzthiazolinone-2-hydrazone solution in acid media by means of a turning coil sampler tube through which air and aqueous solution flow concurrently (François et al 2005 ; Lee and Wang 2004 ; Sauer et al 2003 ), derivatisation with a blue cation UV detected by light reflection through a capillary. Liquid core waveguide LCW (810 μm i.d.)…”
Section: Methodsmentioning
confidence: 99%
“…The derivatization method with 2,4-DNPH is sensitive but the hydrazone is not always stable and reacts with ozone and other air oxidants. In most cases, spectrometric techniques such as Fourier Transform InfraRed absorption (FTIR) [7], [8], Tunable Diode Laser Absorption Spectroscopy (TDLAS) [9] and Differential Optical Absorption Spectroscopy (DOAS) [10] are specific, quantitative and offer a high time resolution (few minutes). However, these instrumentations are heavy, bulky, expensive and usually need to be handle by a specialist.…”
Section: Introductionmentioning