Tumor localization accuracy for high-precision radiotherapy during active breath-hold

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
11
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 37 publications
1
11
0
Order By: Relevance
“…In addition, lung volumes in DIBH may not necessarily always be the same for every breath-hold, although SGRT may confirm a match within a ROI on the patient's body surface to the corresponding reference surface. Such variations in lung volumes during breath-hold were recently reported to have an impact on target localization (31).…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…In addition, lung volumes in DIBH may not necessarily always be the same for every breath-hold, although SGRT may confirm a match within a ROI on the patient's body surface to the corresponding reference surface. Such variations in lung volumes during breath-hold were recently reported to have an impact on target localization (31).…”
Section: Discussionmentioning
confidence: 98%
“…Previous work on employing active breathing coordinator (ABC TM )-controlled breath-hold for lung and liver SBRT reported good intrafractional reproducibility of liver position in the majority of patients. However, interfractional reproducibility was worse, suggesting a need for daily image guidance ( 31 33 ). Another study, conducted by Lu et al, also found higher interfractional than intrafractional motion but observed clinically significant intrafractional motion >3 mm in 26 and 47% of patients with liver and lung cancer, respectively ( 34 ).…”
Section: Discussionmentioning
confidence: 99%
“…Lung volumes can change throughout inspiration repetitions during treatment, however the surface within the ROI may remain similar giving a false sense of security. Lung volume changes during treatment may impact target localisation and this needs to be further evaluated when using SG [24] .…”
Section: Discussionmentioning
confidence: 99%
“…Deep inspiration breath hold with the Active Breathing Coordinator device (ABC-DIBH) can minimize breathing motion and consequently augments cardiac sparing in radiotherapy of breast cancer by increasing the distance between heart and PTV. In contrast to self-sustained breath hold (4.1% variability of lung volume), the ABC device was proved with better intra-session and inter-session reproducibility of respiratory capacity (1.8% and 3% variability of lung volume) on account of the function that induced breath hold automatically at a preset inhaled or exhaled air volume during a predetermined time ( 14 , 15 ). Note that the ABC device utilizes the sensor to count the rotations of turbine impeller for a known respiratory capacity.…”
Section: Introductionmentioning
confidence: 99%