2018
DOI: 10.1016/j.talanta.2018.02.046
|View full text |Cite
|
Sign up to set email alerts
|

Tube radial distribution chromatography system developed by combining commercially available HPLC system and open-tubular capillary tube as separation column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 17 publications
0
11
0
Order By: Relevance
“…The theoretical elution times of the TRDC system were determined assuming that the stationary phase is not static and flows slowly relative to the mobile phase, according to a parabolic curve of linear velocity under laminar flow conditions. The parabolic curves for the organic solvent-rich and water-rich eluent solution can be drawn [10,12] under the present conditions as shown in Fig. 6.…”
Section: Estimation Of Elution Times For Analytesmentioning
confidence: 90%
See 1 more Smart Citation
“…The theoretical elution times of the TRDC system were determined assuming that the stationary phase is not static and flows slowly relative to the mobile phase, according to a parabolic curve of linear velocity under laminar flow conditions. The parabolic curves for the organic solvent-rich and water-rich eluent solution can be drawn [10,12] under the present conditions as shown in Fig. 6.…”
Section: Estimation Of Elution Times For Analytesmentioning
confidence: 90%
“…Under certain conditions, annular flow consisting of inner and outer phases can be observed as a phase-separation multiphase flow, which we call tube radial distribution flow (TRDF). Novel open-tubular capillary chromatography has been performed based on specific TRDF, which we name separation method tube radial distribution chromatography (TRDC) [9,10]. The outer phase in TRDF acts as a pseudo-stationary phase under laminar flow conditions during chromatographic separation.…”
Section: Introductionmentioning
confidence: 99%
“…In contrast, when the mixed solution was fed into a microspace, such as capillary tubes and microchannels on a microchip, annular flow with inner and outer phases was generated under certain conditions; we call this "Tube Radial Distribution Flow" (TRDF). The specific microfluidic flow, TRDF, was applied to capillary liquid chromatography [8] and micro-extraction [9].…”
Section: Introductionmentioning
confidence: 99%
“…TRDF, annular flow in a micro-space, has been applied to new types of chromatography, extraction, mixing, and micro-reactor systems. [4][5][6] We previously attempted to separate and collect the two phases, i.e., the inner and outer phases, in the TRDF by using a micro-flow system with different inner diameter double tubes 7,8 and a microchip incorporating a triple-branched microchannel. 9,10 The flow lines were complicated, and it was difficult to use them in practice.…”
Section: Introductionmentioning
confidence: 99%