2010
DOI: 10.1016/j.nucengdes.2010.03.022
|View full text |Cite
|
Sign up to set email alerts
|

Tube failures due to cooling process problem and foreign materials in power plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
4
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 7 publications
1
4
0
Order By: Relevance
“…Short-term overheating due to oxide scaling was more likely to occur in horizontal superheaters. These patterns are consistent with findings reported in the literature [2,11,4,12]. Some plant operating procedures attempt to reduce the risk of short-term overheating occurrences by constantly monitoring saturation temperatures within the boiler and ensuring that steam temperatures remain above saturation temperatures.…”
Section: Introductionsupporting
confidence: 89%
See 2 more Smart Citations
“…Short-term overheating due to oxide scaling was more likely to occur in horizontal superheaters. These patterns are consistent with findings reported in the literature [2,11,4,12]. Some plant operating procedures attempt to reduce the risk of short-term overheating occurrences by constantly monitoring saturation temperatures within the boiler and ensuring that steam temperatures remain above saturation temperatures.…”
Section: Introductionsupporting
confidence: 89%
“…Short-term overheating is one of the most common and destructive boiler failures that occur in fossil-fuelled power plants. The damage and associated cost of repair has led to in situ cases being studied extensively to determine the root cause of these failures [1,2,3,4]. Short-term overheating is a premature failure that occurs when the tube is exposed to higher than its design temperature, reducing the material's lifetime drastically until it ruptures.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…; further, during the maintenance period, inspection of the oxide scale accumulation conditions should be performed regularly; in addition, for newly installed tubes, careful inspection of the inner flow space to ensure no foreign objects staying inside the tubes is essential. Reference , for example, reported a failure accident caused by crumples of paper inside the tubes.…”
Section: Resultsmentioning
confidence: 99%
“…As a result, ANNs, by definition, exclude the inclusion of any fundamental relationships inherent to the system. This deficiency is particularly noteworthy for the issue of pH control, as a tremendous body of scientific work has identified many of the causal factors (Bhatt, 2006;Viswanathan et al, 2006;Li et al, 2010;Ahmad et al, 2010;Booth and Mead, 1969;Bridle, 2006;Schulze and Eberhard, 1992).…”
Section: Artificial Neural Networkmentioning
confidence: 99%