2021
DOI: 10.2459/jcm.0000000000001208
|View full text |Cite
|
Sign up to set email alerts
|

TrueVue transillumination volume rendering for three-dimensional transoesophageal echocardiography in interventional imaging

Abstract: Aims The aim of the present article is to address the advantages of real-time TrueVue transillumination rendering for three-dimensional transoesophageal echocardiography in the context of echocardiographic procedural guidance for structural interventions for several procedural concerns.Methods Procedures in which transillumination imaging was used during at least one step of the whole intervention were retrospectively collected; the loops were reviewed by an experienced imaging specialist and the most importan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 15 publications
(42 reference statements)
0
3
0
Order By: Relevance
“…Furthermore, new transillumination volume-rendering tools ( Figure 2 ) improve accuracy of anatomic analysis of MV either in pre-procedural planning and intra-procedural guidance by solving the concerns regarding the cavity-structure contrast. 15 Finally, offline multi-plane reconstruction of 3D data sets renders a more precise quantification of MV regurgitation, showing better agreement with CMR in evaluating regurgitant volume than 2DE in eccentric, multiple and late-systolic regurgitant jets. 4 For patients with secondary MR the presence of sufficient leaflet tissue for mechanical coaptation is mandatory and therefore the measurements of the coaptation depth, the coaptation length and posterior and anterior leaflets dimensions are essential.…”
Section: Leaflet Repair: Percutaneous Edge-to-edgementioning
confidence: 97%
“…Furthermore, new transillumination volume-rendering tools ( Figure 2 ) improve accuracy of anatomic analysis of MV either in pre-procedural planning and intra-procedural guidance by solving the concerns regarding the cavity-structure contrast. 15 Finally, offline multi-plane reconstruction of 3D data sets renders a more precise quantification of MV regurgitation, showing better agreement with CMR in evaluating regurgitant volume than 2DE in eccentric, multiple and late-systolic regurgitant jets. 4 For patients with secondary MR the presence of sufficient leaflet tissue for mechanical coaptation is mandatory and therefore the measurements of the coaptation depth, the coaptation length and posterior and anterior leaflets dimensions are essential.…”
Section: Leaflet Repair: Percutaneous Edge-to-edgementioning
confidence: 97%
“…Single antiplatelets therapy is recommended for TAVI patients without indication for OAC. Furthermore, OAC therapy, when not indicated, failed to reduce the incidence of valve dysfunction and stroke and resulted in a rise in mortality and bleeding rate 26,27 …”
Section: Aortic Stenosismentioning
confidence: 99%
“…Furthermore, OAC therapy, when not indicated, failed to reduce the incidence of valve dysfunction and stroke and resulted in a rise in mortality and bleeding rate. 26,27…”
Section: Aortic Stenosismentioning
confidence: 99%