2011
DOI: 10.1016/j.desal.2010.08.020
|View full text |Cite
|
Sign up to set email alerts
|

Troubleshooting of crude oil desalination plant using fuzzy expert system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 13 publications
0
6
0
1
Order By: Relevance
“…The refinery's crude oil distillation unit processes crude oil by breaking it down into useful product fractions. The most important components for the distillation systems in the oil refinery are pre-flashed drums, heat exchanger systems and atmospheric distillation units [21]. Hydrogen sulphide may damage the tower and condenser if dissolved in the aqueous condensation from the top refluxed barrels of the main fractionation column and water from the vacuum distillation unit.…”
Section: The Unit Desalination Of Crude Oilmentioning
confidence: 99%
“…The refinery's crude oil distillation unit processes crude oil by breaking it down into useful product fractions. The most important components for the distillation systems in the oil refinery are pre-flashed drums, heat exchanger systems and atmospheric distillation units [21]. Hydrogen sulphide may damage the tower and condenser if dissolved in the aqueous condensation from the top refluxed barrels of the main fractionation column and water from the vacuum distillation unit.…”
Section: The Unit Desalination Of Crude Oilmentioning
confidence: 99%
“…Rule-based reasoning usually requires some boundaries to distinguish certain process states. In order to handle uncertainties in these boundaries, fuzzy logic has been introduced in expert system (Feng et al, 1998;Zahedi et al, 2011).…”
Section: Expert Systemmentioning
confidence: 99%
“…For example, Abdul‐Wahab et al [ 22 ] have applied an FES as a real‐time troubleshooting tool in the complex brine heater problem. Similarly, Zahedi et al [ 23 ] have implemented an FES for troubleshooting purposes in crude oil desalination plants. Chuk et al [ 24 ] have used an FES to monitor the ratio of concentrated froth solid‐to‐liquids in the float column.…”
Section: Introductionmentioning
confidence: 99%