2018
DOI: 10.1016/j.fusengdes.2018.04.115
|View full text |Cite
|
Sign up to set email alerts
|

Tritium release from molten salt FLiNaK under low flux neutron irradiation with an AmBe neutron source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 9 publications
1
4
0
Order By: Relevance
“…soluble. That was similar to the result for the previous irradiation experiments on FLiNaK in which most of the tritium recovered was the released tritium and soluble [6]. A larger amount of insoluble HT was expected to be recovered from FLiNaBe than from FLiNaK because of a smaller amount of free F − ions in FLiNaBe forming clusters, e.g., BeF 2− 4 and Be 2 F 3− 7 , due to the high reducibility of Be [17,18].…”
Section: Chemical Forms Of Tritium Recovered From Flinabesupporting
confidence: 87%
See 3 more Smart Citations
“…soluble. That was similar to the result for the previous irradiation experiments on FLiNaK in which most of the tritium recovered was the released tritium and soluble [6]. A larger amount of insoluble HT was expected to be recovered from FLiNaBe than from FLiNaK because of a smaller amount of free F − ions in FLiNaBe forming clusters, e.g., BeF 2− 4 and Be 2 F 3− 7 , due to the high reducibility of Be [17,18].…”
Section: Chemical Forms Of Tritium Recovered From Flinabesupporting
confidence: 87%
“…Table 1 shows the overall mass transfer coefficients for FLiNaBe at 773 K obtained with the curve fitting, where K 1 and K 2 are the coefficients for the released tritium and the permeated tritium, respectively. The table also shows the results for FLiNaK at 773 K obtained in the previous study [6]. There was no significant difference between the overall mass transfer coefficients for FLiNaBe and FLi-NaK.…”
Section: Comparison Of the Overall Mass Transfer Coefficients For Trimentioning
confidence: 60%
See 2 more Smart Citations
“…Figure 3 shows the schematic of a tritium sampler system, which is composed of an Ar gas flow system, a closed stainless-steel container, an electric furnace, and water bubbling tubes [25][26][27]. The core sample weighing approximately 8 g in the closed, stainless-steel container was heated by an electric furnace at 400 • C flowing Ar gas.…”
Section: Tritium Measurementmentioning
confidence: 99%