2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/R 2016
DOI: 10.1109/nssmic.2016.8069882
|View full text |Cite
|
Sign up to set email alerts
|

Triroc, a versatile 64-channel SiPM readout ASIC for time-of-flight PET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 1 publication
0
12
0
Order By: Relevance
“…Compared to other ASICs the TOFPET2 ASIC features a similar or even lower power consumption. For other models, higher values are often reported, e.g., 10 mW/channel for the Triroc ASIC, 25 mW/channel for the STIC3 ASIC, and less than 40 mW/channel for the PETA4 ASIC [18], [20], [21]. The prior version of the TOFPET2 ASIC also featured a slightly higher power consumption (8 mW/channel to 11 mW/channel) [30].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Compared to other ASICs the TOFPET2 ASIC features a similar or even lower power consumption. For other models, higher values are often reported, e.g., 10 mW/channel for the Triroc ASIC, 25 mW/channel for the STIC3 ASIC, and less than 40 mW/channel for the PETA4 ASIC [18], [20], [21]. The prior version of the TOFPET2 ASIC also featured a slightly higher power consumption (8 mW/channel to 11 mW/channel) [30].…”
Section: Discussionmentioning
confidence: 99%
“…For SiPM readout in PET applications, the precise digitization of event timestamps and energies is typically achieved by employing application-specific integrated circuits (ASICs). These ASICs typically support 8 to 64 data channels [12]- [20]. The time binning of the employed time-to-digital converters (TDC) can range from 20 ps-50 ps [18], [19], [21], [22].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…If we take the coincidence time resolution (CTR FWHM ) of a full detection system as a figure of merit to compare ASICs in terms of the timing performance (to be compared with similar scintillator and photodetector conditions), we can observe a continuous improvement trend. Considering LYSO crystals and 3 × 3 mm 2 pixels, the TRIROC ASIC (2016 [ 40 ]) achieved 423 ps, TOFPET (2016) 294 ps and STiC (2018 [ 41 ]) 214 ps. For smaller pixels (2 × 2 mm 2 ) FlexToT v2 reached 123 ps and NINO (2017) 93 ps [ 42 ].…”
Section: Multi-modal Medical Imagingmentioning
confidence: 99%