Triple-head gamma camera PET: system overview and performance characteristics

Abstract: Positron emission tomography (PET) is currently performed using either a dedicated PET scanner or scintillation gamma camera equipped with electronic circuitry for coincidence detection of 511 keV annihilation quanta (gamma camera PET system). Although the resolution limits of these two instruments are comparable, the sensitivity and count rate performance of the gamma camera PET system are several times lower than that of the PET scanner. Most gamma camera PET systems are manufactured as dual-detector systems… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
1
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 7 publications
2
1
0
Order By: Relevance
“…In situations when this is possible, the results obtained for this camera compare extremely well to those from other similar systems [2], [5]. It is interesting to notice that although the sensitivity values are relatively low due to the presence of the 3″ thick collimators, the peak NECR exceeds that of other dual-head cameras [2].…”
Section: Discussionsupporting
confidence: 75%
“…In situations when this is possible, the results obtained for this camera compare extremely well to those from other similar systems [2], [5]. It is interesting to notice that although the sensitivity values are relatively low due to the presence of the 3″ thick collimators, the peak NECR exceeds that of other dual-head cameras [2].…”
Section: Discussionsupporting
confidence: 75%
“…When this is possible, the results obtained for this camera compare extremely well to those from other similar systems [2,5]. It is interesting to notice that although the sensitivity values are relatively low due to the presence of the 3" thick collimators, the peak NECR exceeds that of other dual head cameras [2].…”
Section: Discussionsupporting
confidence: 74%
“…A detailed system description and performance characteristics are given elsewhere. 20,21 About 370 MBq (10 mCi) of 18 F-FDG was administered intravenously to each patient after overnight fasting. Patients received a diuretic to minimize artefacts due to urinary stasis and were kept well hydrated.…”
Section: Fdg-petmentioning
confidence: 99%