2016
DOI: 10.1016/j.arth.2016.02.027
|View full text |Cite
|
Sign up to set email alerts
|

Tribocorrosion: Ceramic and Oxidized Zirconium vs Cobalt-Chromium Heads in Total Hip Arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
50
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(54 citation statements)
references
References 26 publications
2
50
2
Order By: Relevance
“…Although the taper designs used in the head–stem neck junction were varied, a single design head–stem neck junction was used in this study. In any case, all previous studies showed evidence of some fretting and corrosion, as expected from any modular taper connection . We believe that this drawback is partially offset by the various controlled laboratory conditions of the hip simulator test used in this study.…”
Section: Discussionmentioning
confidence: 58%
See 1 more Smart Citation
“…Although the taper designs used in the head–stem neck junction were varied, a single design head–stem neck junction was used in this study. In any case, all previous studies showed evidence of some fretting and corrosion, as expected from any modular taper connection . We believe that this drawback is partially offset by the various controlled laboratory conditions of the hip simulator test used in this study.…”
Section: Discussionmentioning
confidence: 58%
“…In any case, all previous studies showed evidence of some fretting and corrosion, as expected from any modular taper connection. 37,38 We believe that this drawback is partially offset by the various controlled laboratory conditions of the hip simulator test used in this study. Furthermore, work will focus on performing hip-simulator wear tests using larger (i.e., 40 or 44 mm) ZTA ceramic and Co-Cr-Mo alloy femoral heads against the Ti-6Al-4V alloy trunnion with a 12/14 mm taper.…”
Section: Discussionmentioning
confidence: 97%
“…Because of the relatively small sample size (401 revisions for PJI out of 84,894 hips), subgrouping the data set according to head diameter was considered not meaningful. We acknowledge that hips with large metal heads are more at risk of generating a milieu for PJI because of potential taper corrosion, whereas in contrast, ceramic heads can protect the patient from this complication [13,14]. Analysis of bilateral THAs as independent observations is a potential statistical flaw of the study.…”
Section: Discussionmentioning
confidence: 99%
“…A deeper level of score granularity can provide more details about the severity and spatial distribution of damage. Distribution of the corrosion damage over the distinct zones of tapers has been investigated by a limited number of studies [8,[11][12][13][14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%