2007
DOI: 10.1049/el:20072649
|View full text |Cite
|
Sign up to set email alerts
|

Triangular resonator based on surface plasmon resonance of attenuated reflection mirror

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 4 publications
1
4
0
Order By: Relevance
“…This number is similar to previously reported wavelength-shift sensitivity for many nanoplasmonic structures reported thus far [25] (e.g. 400 nm/RIU (@1600 nm) for nanopatterns [26], 637 nm/RIU (@300-1800 nm) for nanoparticles [27], 300∼560 nm/RIU (@600-900 nm) for nanoslit arrays [28], 600 nm/RIU (@1460 nm) for disk resonator [29], ∼1500 nm/RIU (@1550 nm) for nanohole arrays [24], [30], etc.). However, it should be noted that the FWHM of the launched SPP mode under this coupling mechanism is relatively sharp [e.g.…”
Section: Numerical Simulation Of Optical Sensingsupporting
confidence: 91%
“…This number is similar to previously reported wavelength-shift sensitivity for many nanoplasmonic structures reported thus far [25] (e.g. 400 nm/RIU (@1600 nm) for nanopatterns [26], 637 nm/RIU (@300-1800 nm) for nanoparticles [27], 300∼560 nm/RIU (@600-900 nm) for nanoslit arrays [28], 600 nm/RIU (@1460 nm) for disk resonator [29], ∼1500 nm/RIU (@1550 nm) for nanohole arrays [24], [30], etc.). However, it should be noted that the FWHM of the launched SPP mode under this coupling mechanism is relatively sharp [e.g.…”
Section: Numerical Simulation Of Optical Sensingsupporting
confidence: 91%
“…Small amounts of horseradish peroxidase detection have been demonstrated using the MetaSurface sensor in [103]. A significant shift of the resonant peak occurred when presenting a high sensitivity (600 nm/RIU [104]) for femtomole level of sensed targets. Planar wallpaper MetaSurface (hexagonal and square unit cells) were also utilized for protein detection such as biotin [105] and bovine serum albumin (BSA) molecules [106].…”
Section: Resultsmentioning
confidence: 99%
“…Theoretical analyses of ring resonators and applications using various ring shapes have been actively investigated by researchers. In particular, Kim et al , in 2007, demonstrated a novel biosensor based on the triangular resonator with TIR and ATR mirrors to achieve compactness and a high sensitivity [ 72 ].…”
Section: Other Typesmentioning
confidence: 99%