2009
DOI: 10.1016/j.ijms.2009.04.007
|View full text |Cite
|
Sign up to set email alerts
|

Triacetone triperoxide detection using low reduced-field proton transfer reaction mass spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
39
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 49 publications
(41 citation statements)
references
References 25 publications
(37 reference statements)
2
39
0
Order By: Relevance
“…PTR-MS instrument. This present study was performed on our home-made PTR-MS apparatus (Ion Sniffer 2020Q) as described in our previous work [21][22][23][24][25][26] and a detailed description of PTR-MS technique can be found elsewhere 21,27,28 . Briefly, the apparatus mainly contains ion source, drift tube and quadrupole mass spectrometer (QMS).…”
Section: Methodsmentioning
confidence: 99%
“…PTR-MS instrument. This present study was performed on our home-made PTR-MS apparatus (Ion Sniffer 2020Q) as described in our previous work [21][22][23][24][25][26] and a detailed description of PTR-MS technique can be found elsewhere 21,27,28 . Briefly, the apparatus mainly contains ion source, drift tube and quadrupole mass spectrometer (QMS).…”
Section: Methodsmentioning
confidence: 99%
“…Proton transfer reaction (PTR)-MS with H 3 O þ and NH 4 þ as the reagent ions has been used to detect TATP. It was shown that in reduced electric field typical protonated [TATPþH] þ and adduct [TATPþNH 4 ] þ ions are formed, respectively (Shen et al, 2009). In recent article five different high explosives were analyzed comparatively with two different PTR-TOFMS instruments.…”
Section: Spectrometry For Explosivesmentioning
confidence: 99%
“…Finally, two examples were used to illustrate this method: (1) the direct identification of cyclohexanone as the major component in the headspace of medical infusion sets, and (2) the differentiation and quantification of propanal and acetone in three synthetic mixtures with different ratios of 15.2%/84.8%, 45.8%/54.2% and 64.6%/35.4%. The demonstration of its construction and performance has been reported elsewhere [5,7,19]. The schematic of Hefei PTR-MS-01 is shown in Figure 1.…”
Section: Introductionmentioning
confidence: 99%
“…Due to its advantages, such as fast response time (to 200 ms), absolute concentration measurements, and low detection limit (low ppt range), PTR-MS has been used in many fields, such as environmental research, science and technology for food and flavour, physiology and medicine, detection of explosives and screening drug precursor chemicals in recent years [1][2][3][4][5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%