2021
DOI: 10.3390/app11020501
|View full text |Cite
|
Sign up to set email alerts
|

Trends in Performance Limits of the HOT Infrared Photodetectors

Abstract: The cryogenic cooling of infrared (IR) photon detectors optimized for the mid- (MWIR, 3–5 µm) and long wavelength (LWIR, 8–14 µm) range is required to reach high performance. This is a major obstacle for more extensive use of IR technology. Focal plane arrays (FPAs) based on thermal detectors are presently used in staring thermal imagers operating at room temperature. However, their performance is modest; thermal detectors exhibit slow response, and the multispectral detection is difficult to reach. Initial ef… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
42
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 58 publications
(42 citation statements)
references
References 71 publications
0
42
0
Order By: Relevance
“…Table 5 shows the significant parameters of the antimony detector (present work) as compared to common types of IR detectors 31,32 . The antimony detector has a very comparable detectivity to PdSe 2 -MoSe 2 heterostructure detector; despite the very large area of the antimony detector.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Table 5 shows the significant parameters of the antimony detector (present work) as compared to common types of IR detectors 31,32 . The antimony detector has a very comparable detectivity to PdSe 2 -MoSe 2 heterostructure detector; despite the very large area of the antimony detector.…”
Section: Resultsmentioning
confidence: 99%
“…Table 5. A comparison of present work (antimony detector parameters) with commercial IR detectors 31,32 . The current study has successfully completed its intended objective, which included the fabrication of self-powered, room-temperature, low-noise, fast, and highly responsive broad-band antimony detectors.…”
Section: Resultsmentioning
confidence: 99%
“…4d). The available Q-factors are in the range of [15][16][17][18][19][20][21][22][23][24][25]) and ) respectively, which surpass that of graphene plasmon resonance in the THz regime 45 .…”
Section: Far-field Excitation Of Tunable Thz Hphps Using Periodic Tun...mentioning
confidence: 99%
“…At room temperature, the detection efficiency of these detectors is around 3 orders of magnitude smaller than Si-based photodiodes. , Therefore, cryogenic cooling (down to 77 K) is needed to achieve an acceptable signal-to-noise ratio. Despite continuous efforts in the community for advancing mid-IR detectors, a viable alternative relies on using nonlinear optical phenomena. In this case, the interaction of a specimen with the probing IR light can be revealed from the detection of the visible/near-IR (NIR) light, where efficient Si detectors can be used.…”
Section: Introductionmentioning
confidence: 99%