The literature on hemodynamic responses during inspiratory muscle exercise (IME) lacks a consensus. To evaluate and compare hemodynamic responses during an IME session with and without resistive load, 15 sedentary men were subjected to two randomized IME sessions: one with 40% of maximal inspiratory pressure (IME 40%) and another without a resistive load (Sham), both of which were performed for two minutes over eight sessions with one-minute intervals. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP), total peripheral resistance (TPR), stroke volume (SV), cardiac output (CO), and heart rate (HR) were measured by infrared digital photoplethysmography during five basal minutes and during the IME sessions. One-way analysis of variance and the Student’s t test for paired data were used to analyze hemodynamic response and delta values between sessions. Effect size was evaluated by Cohen’s D. A 5% significance level was adopted. SBP responses (sham: ∆−1±2 vs. 40%: ∆−4±2mmHg, p=0.27), DBP (sham: ∆2±1 vs. 40%: ∆1±2mmHg, p=0.60) and MBP (sham: ∆2±1 vs. 40%: ∆0±2mmHg, p=0.28) were similar between sessions. HR increases were higher in the 40% IME session than in the sham session (sham: ∆9±2 vs. 40%: ∆3±2bpm, p=0.001). SV only decreased during the sham session but responses were similar between sessions (sham: ∆−2±2 vs. IME 40%: ∆−6±2ml, p=0.13). Both sessions did not change SBP, DBP, MBP, CO, and TPR, but we observed a greater increase in HR in the IME 40% session. Only the Sham session decreased SV.
The literature on hemodynamic responses during inspiratory muscle exercise (IME) lacks a consensus. To evaluate and compare hemodynamic responses during an IME session with and without resistive load, 15 sedentary men were subjected to two randomized IME sessions: one with 40% of maximal inspiratory pressure (IME 40%) and another without a resistive load (Sham), both of which were performed for two minutes over eight sessions with one-minute intervals. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP), total peripheral resistance (TPR), stroke volume (SV), cardiac output (CO), and heart rate (HR) were measured by infrared digital photoplethysmography during five basal minutes and during the IME sessions. One-way analysis of variance and the Student’s t test for paired data were used to analyze hemodynamic response and delta values between sessions. Effect size was evaluated by Cohen’s D. A 5% significance level was adopted. SBP responses (sham: ∆−1±2 vs. 40%: ∆−4±2mmHg, p=0.27), DBP (sham: ∆2±1 vs. 40%: ∆1±2mmHg, p=0.60) and MBP (sham: ∆2±1 vs. 40%: ∆0±2mmHg, p=0.28) were similar between sessions. HR increases were higher in the 40% IME session than in the sham session (sham: ∆9±2 vs. 40%: ∆3±2bpm, p=0.001). SV only decreased during the sham session but responses were similar between sessions (sham: ∆−2±2 vs. IME 40%: ∆−6±2ml, p=0.13). Both sessions did not change SBP, DBP, MBP, CO, and TPR, but we observed a greater increase in HR in the IME 40% session. Only the Sham session decreased SV.
RESUMO A literatura carece de um consenso sobre respostas hemodinâmicas durante o exercício muscular inspiratório (EMI). Este estudo buscou avaliar e comparar as respostas hemodinâmicas durante uma sessão de EMI com e sem carga resistiva. Para tanto, 15 homens sedentários foram submetidos a duas sessões randomizadas de EMI: 40% da pressão inspiratória máxima (EMI 40%) e sem carga resistiva (sham), realizadas por dois minutos em oito sessões e com intervalos de um minuto. A pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), pressão arterial média (PAM), resistência periférica total (RPT), volume sistólico (VS), débito cardíaco (DC) e frequência cardíaca (FC) foram medidos por fotopletismografia infravermelha digital por cinco minutos basais e durante as sessões de EMI. Anova de uma via e o teste t de Student para dados pareados foram usados para analisar a resposta hemodinâmica e os valores delta entre as sessões. O tamanho do efeito foi avaliado pelo d de Cohen. Adotou-se nível de significância de 5%. As respostas de PAS (sham: ∆−1±2 vs. 40%: ∆−4±2mmHg, p=0,27), PAD (sham: ∆2±1 vs. 40%: ∆1±2mmHg, p=0,60) e PAM (sham: ∆2±1 vs. 40%: ∆0±2mmHg, p=0,28) foram semelhantes entre as sessões. Os aumentos da FC foram maiores na sessão de EMI 40% do que nas sessões sham (sham: ∆9±2 vs. 40%: ∆3±2bpm, p=0,001). O VS diminuiu exclusivamente durante a sessão sham mas a resposta foi semelhante entre as sessões (sham: ∆−2±2 vs. EMI 40%: ∆−6±2ml, p=0,13). Ambas as sessões não causaram alteração nas variáveis PAS, PAD, PAM, DC e RPT, mas notamos um aumento maior da FC na sessão EMI 40%. Apenas a sessão sham reduziu o VS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.