2023
DOI: 10.1016/j.brachy.2022.11.012
|View full text |Cite
|
Sign up to set email alerts
|

Treatment verification in high dose rate brachytherapy using a realistic 3D printed head phantom and an imaging panel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 27 publications
0
1
0
Order By: Relevance
“…Several reports have noted the importance of error detection in brachytherapy. 22,23 While various technologies exist and have been proven to be effective, besides EMT also invivo dosimetry [34][35][36] and imaging panels, [37][38][39] very few of them are used in routine clinical workflows to date. For this reason, comprehensive knowledge about the prevalence of clinical treatment errors is still lacking.…”
Section: Discussionmentioning
confidence: 99%
“…Several reports have noted the importance of error detection in brachytherapy. 22,23 While various technologies exist and have been proven to be effective, besides EMT also invivo dosimetry [34][35][36] and imaging panels, [37][38][39] very few of them are used in routine clinical workflows to date. For this reason, comprehensive knowledge about the prevalence of clinical treatment errors is still lacking.…”
Section: Discussionmentioning
confidence: 99%
“…New software was developed in-house to calculate the dose delivered during an HDR brachytherapy treatment (section 2.1) from dwell times and source positions obtained using an IP (imaging panel)-based source tracking approach (Fonseca et al 2021, van Wagenberg et al 2023. The aim of this software is to calculate the dose that was delivered to the patient, and compare it against the planned dose to find treatment deviations.…”
Section: Methodsmentioning
confidence: 99%
“…To evaluate and showcase the tool developed in section 2.1, measurements in a phantom were performed in accordance to earlier work, see figure 1. (Fonseca et al 2021, van Wagenberg et al 2023 First, a realistic treatment plan was created for a prostate case (section 2.2). This treatment plan was delivered and measured in an anthropomorphic pelvic phantom (section 2.3) to verify the approach.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Doyle et al [17] gather recommended phantom and tests by different entities for US systems used in prostate treatments, whereas recommendations for the commissioning, quality control and considerations for MRI acquisitions in HDR brachytherapy can be found in the American Association of Physicists in Medicine (AAPM) TG-303 [18]. On the other hand, recent publications also provide methodologies to verify the Treatment Planning System (TPS) or for treatment verification in HDR brachytherapy [19,20].…”
Section: Introductionmentioning
confidence: 99%