2002
DOI: 10.2106/00004623-200203000-00007
|View full text |Cite
|
Sign up to set email alerts
|

TREATMENT OF REVERSE OBLIQUE AND TRANSVERSE INTERTROCHANTERIC FRACTURES WITH USE OF AN INTRAMEDULLARY NAIL OR a 95° SCREW-PLATE

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
192
2
12

Year Published

2005
2005
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 340 publications
(208 citation statements)
references
References 14 publications
2
192
2
12
Order By: Relevance
“…23,24 One study specifically looked at transverse and reverse oblique (often classified as subtrochanteric, analogous to a Seinsheimer IIC fracture) intertrochanteric fractures as per the classification of the Orthopaedic Trauma Association, but excluded fractures extending ≥5 cm from the distal lesser trochanter. 25 An implant failure rate of 32% in the fixed-angle plating (Dynamic Condylar Screw) group versus zero in the intramedullary nailing group (Proximal Femoral Nail) was reported. 25 Despite anatomic reduction, the mode of failure in the BP group was from plate or screw breakage (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…23,24 One study specifically looked at transverse and reverse oblique (often classified as subtrochanteric, analogous to a Seinsheimer IIC fracture) intertrochanteric fractures as per the classification of the Orthopaedic Trauma Association, but excluded fractures extending ≥5 cm from the distal lesser trochanter. 25 An implant failure rate of 32% in the fixed-angle plating (Dynamic Condylar Screw) group versus zero in the intramedullary nailing group (Proximal Femoral Nail) was reported. 25 Despite anatomic reduction, the mode of failure in the BP group was from plate or screw breakage (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Autores são de opinião que a haste PFN ® possibilita a obtenção de excelentes resultados no tratamento da fratura trocantérica instável do fêmur, principalmente quanto à estabilidade propiciada pelo implante, que permite deambulação precoce com melhor reabilitação funcional do paciente idoso e alto índice de consolidação decorrente da preservação do envelope de partes moles em torno da fratura (37)(38)(39)(40) .…”
Section: Discussionunclassified
“…In a prospective randomized study of 210 patients with intertrochanteric fractures treated with either a SHS or a long Gamma 1 nail, Barton et al [3] found no differences between groups in reoperation rates, mortality rates, or EuroQol 5D scores. Although many surgeons prefer a SHS for fixing stable fractures [4,24,26], the intramedullary nail (IMN) reportedly has greater mechanical resistance to failure, a loadbearing device, and thus increased mechanical stability in unstable fractures, especially the reverse oblique types [15,20,22]. The proximal thick part of the nail leans against the proximal fragment preventing medialization of the shaft.…”
Section: Introductionmentioning
confidence: 99%