2009
DOI: 10.1016/j.main.2009.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Treatment of complex proximal interphalangeal joint fractures using a new dynamic external fixator: 15 cases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
21
2
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(25 citation statements)
references
References 20 publications
0
21
2
2
Order By: Relevance
“…Secondary fracture dislocation with the PRTS is described by Syed in 2 out of 8 and by Morgan in 5 out of 14 cases (Morgan, 1995, #14; Syed, 2003, #13). This could not be observed in our Ligamentotaxor® group but is described by Körting et al in 1 out of 15 patients treated with Ligamentotaxor® [7]. An interesting aspect of any dynamic fixator system is the long-term improvement of flexion mobility found 8 years after PRTS use.…”
Section: Discussioncontrasting
confidence: 44%
“…Secondary fracture dislocation with the PRTS is described by Syed in 2 out of 8 and by Morgan in 5 out of 14 cases (Morgan, 1995, #14; Syed, 2003, #13). This could not be observed in our Ligamentotaxor® group but is described by Körting et al in 1 out of 15 patients treated with Ligamentotaxor® [7]. An interesting aspect of any dynamic fixator system is the long-term improvement of flexion mobility found 8 years after PRTS use.…”
Section: Discussioncontrasting
confidence: 44%
“…16) Other recent studies on the Ligamentotaxor have reported similar results with average ROM at the PIPJ of up to 73°. 15) This is alongside improved grip strengths and DASH scores. The better results are possibly related to the longer follow up of those patients.…”
Section: Discussionmentioning
confidence: 93%
“…4) Advocates suggest the Ligamentotaxor offers additional benefits through its spring-tensioned ligamentotaxis preventing chondral collapse at the fracture site. 15) This aids joint remodeling whilst preventing intra-articular adhesions and capsuloligamentous contracture. 15) Additionally the system allows more precise wire placement and more reproducible results.…”
Section: Discussionmentioning
confidence: 99%
“…Ligamentotaxor® (AREX,Palaiseau, Fransa) sistemi diğer dinamik eksternal fiksayon sistemleri gibi erken eklem hareketini sağlamakta ve tendon yapışıklıkları ile eklem sertliklerini engellediği gösterilmiştir (2,5,11). Bu sistemin bir diğer avantajı öğrenme eğrisinin kısalığı, kullanım kolaylığı ve ağır olmaması sayılabilir (5).…”
Section: Discussionunclassified
“…Bu sistemin bir diğer avantajı öğrenme eğrisinin kısalığı, kullanım kolaylığı ve ağır olmaması sayılabilir (5). Pin enfeksiyonu ve osteoliz bazı dinamik eksternal sistemlerde gösterilmiştir (12)(13)(14).…”
Section: Discussionunclassified