Treatment log files as a tool to identify treatment plan sensitivity to inaccuracies in scanned proton beam delivery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
27
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 33 publications
(27 citation statements)
references
References 18 publications
0
27
0
Order By: Relevance
“…FVBOO method would create a challenge in the measurement‐based patient‐specific qualify assurance (PSQA), which needs to be performed for individual fractions instead of the entire plan. However, the hurdle may be overcome by adopting calculation 28–30 and treatment log file analysis 31–33 based PSQA. Measurement‐based QA can be accelerated via scripting and automated delivery.…”
Section: Discussionmentioning
confidence: 99%
“…FVBOO method would create a challenge in the measurement‐based patient‐specific qualify assurance (PSQA), which needs to be performed for individual fractions instead of the entire plan. However, the hurdle may be overcome by adopting calculation 28–30 and treatment log file analysis 31–33 based PSQA. Measurement‐based QA can be accelerated via scripting and automated delivery.…”
Section: Discussionmentioning
confidence: 99%
“…Although spot shape, size, and position can be measured using conventional scintillator‐based dosimetry systems, such as the Lynx, these systems are difficult to use during patient treatment due to their bulk. Log file‐based dose reconstruction systems showed, however, that these systems can measure dosimetric information in real time using strip chambers inside the nozzle . Although these systems are good for confirming treatment beams and reconstructing doses in patients, they have several limitations.…”
Section: Discussionmentioning
confidence: 99%
“…Log file-based dose reconstruction systems showed, however, that these systems can measure dosimetric information in real time using strip chambers inside the nozzle. [11][12][13] Although these systems are good for confirming treatment beams and reconstructing doses in patients, they have several limitations. First, their resolution in measuring elaborate scanning proton beams with tightly distributed spots, such as pencil beams of a full width half maximum (FWHM) of a few millimeters, is low (2 mm), whereas the GAPSP provides a resolution comparable to that of an EBT3 film.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several reports have commented on the experiences in other institutions of performing patient-specific quality assurance (PSQA) for spot scanning proton beam therapy, describing the need for multiple measurements per field followed by a γ-index analysis on the 2D dose distributions 1,2 . Various additions to complement PSQA in IMPT have been proposed, such as the use of a second check dose engine 3 , and the use of machine treatment log files 46 , or some combination of the two, complemented by measurement 7 . The workflow proposed in this manuscript is a comprehensive approach that incorporates multiple second-check dose engines, a complete log file analysis, as well as dose plane measurements.…”
Section: Introductionmentioning
confidence: 99%