2002
DOI: 10.1046/j.1464-410x.2002.03036.x
|View full text |Cite
|
Sign up to set email alerts
|

Treating neuropathic incontinence in children with seromuscular colocystoplasty and an artificial urinary sphincter

Abstract: Purpose To review the results of artificial urinary sphincter (AUS) implantation combined with seromuscular colocystoplasty (SCLU) in the treatment of mixed neurogenic urinary incontinence in children. Patients and methods Patients (27, six females) who had undergone SCLU were interviewed, and their charts and imaging studies reviewed retrospectively. Their urodynamic data were analysed and bladder capacity, end-filling pressure, safe capacity and percentage of expected capacity for age compared before and aft… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 15 publications
(18 reference statements)
0
3
0
Order By: Relevance
“…Nevertheless, it is questionable which urodynamic parameters are important to determine the need for augmentation (74, 75). In an attempt to reduce the likelihood of intestinal augmentation related complications others have combined the implantation of AUS with a seromuscular colocystoplasty with more than 85 % dryness at 2 years (76, 77). Others have sought to avoid the potential complications of mechanical malfunction of the AUS by implanting only the cuff at the time of an enterocystoplasty but most patients eventually required implantation of the entire AUS system (78).…”
Section: Resultsmentioning
confidence: 99%
“…Nevertheless, it is questionable which urodynamic parameters are important to determine the need for augmentation (74, 75). In an attempt to reduce the likelihood of intestinal augmentation related complications others have combined the implantation of AUS with a seromuscular colocystoplasty with more than 85 % dryness at 2 years (76, 77). Others have sought to avoid the potential complications of mechanical malfunction of the AUS by implanting only the cuff at the time of an enterocystoplasty but most patients eventually required implantation of the entire AUS system (78).…”
Section: Resultsmentioning
confidence: 99%
“…Also the procedure works best in patients with high outlet resistance to prevent early urine leak around the catheter, for example those who have an artificial urinary sphincter or a sling implanted prior or at the time of the augmentation (52). Preoperative measures of leak point pressure are no always reliable as the detrusorectomy can cause a drop in outlet resistance (38).…”
Section: Resultsmentioning
confidence: 99%
“…Hourglass deformity of bladder has been described following seromuscular colocystoplasty in the treatment of mixed neurogenic urinary incontinence in children [4], and in patients who underwent bladder autoaugmentation to treat neuropathic bladder secondary to myelomeningocele [5]. Very rarely hourglass bladder may be a congenital deformity [6].…”
Section: Discussionmentioning
confidence: 99%