2023
DOI: 10.1016/j.compeleceng.2023.108650
|View full text |Cite
|
Sign up to set email alerts
|

Trapezoidal reference-based single carrier pulse width modulation method for multilevel converters with novel FPGA implementation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…It gives many advantages as compared with other conventional SCPWM techniques. [26][27][28][29][30][31][32] The basic definition of FPF is nothing but a difference between the reference signal (RS) and the floor of the reference signal. The FPF function can also be represented as {RS} mathematically expressed in (1).…”
Section: Circuit Description and Operation Of 5l-sci Topology With Di...mentioning
confidence: 99%
See 1 more Smart Citation
“…It gives many advantages as compared with other conventional SCPWM techniques. [26][27][28][29][30][31][32] The basic definition of FPF is nothing but a difference between the reference signal (RS) and the floor of the reference signal. The FPF function can also be represented as {RS} mathematically expressed in (1).…”
Section: Circuit Description and Operation Of 5l-sci Topology With Di...mentioning
confidence: 99%
“…26,27 In Lingom et al, 30 a generalized SCPWM technique with the abs function has been stipulated, but its implementation needs more mathematical expressions and ifelse loops. For obtaining higher quality waveform, the TR-SCPWM method has been proclaimed in Ero glu and Kurto glu, 31 but its implementation needs more if-else loops. This technique is not suitable for closed-loop gridconnected applications, and it is also not possible to integrate with PCCA also.…”
mentioning
confidence: 99%
“…However, the PWM implementation with floor function is very simple compared with all conventional SC-PWM techniques. 19,20,29…”
Section: Application Of Pct and Comparative Studymentioning
confidence: 99%
“…The harmonic performance (IOV) of the LSPWM technique and F 2 ‐SCPWM technique is almost same since the mimic switching behavior of the LSPWM technique is same as the single modulating and SCPWM technique. However, the PWM implementation with floor function is very simple compared with all conventional SC‐PWM techniques 19,20,29 . Table 6 represents a comparative study of different generalized M 2 PC 2 techniques.…”
Section: Application Of Pct and Comparative Studymentioning
confidence: 99%
See 1 more Smart Citation