2019
DOI: 10.1111/jicd.12417
|View full text |Cite
|
Sign up to set email alerts
|

Transportation assessment in artificial curved canals after instrumentation with Reciproc, Reciproc Blue, and XP‐endo Shaper Systems

Abstract: Aim:In the present study, we compared the transportation of three different instrumentation systems in different levels of standardized artificial curved canals. Methods:Sixty epoxy resin blocks containing simulated canals were divided into three groups (n = 20) according to the instrument used for canal preparation: Reciproc (REC), Reciproc Blue (REC Blue), and XP-endo Shaper (XPS). Pre-and post-instrumentation digital images of each specimen were superimposed by Photoshop software to evaluate the different a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
10
0
2

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 34 publications
1
10
0
2
Order By: Relevance
“…Instruments with variable tapers may cause significantly less removal of coronal dentine in comparison with continuously tapered instruments whilst also providing adequate apical enlargement (Almeida et al 2019). Different results were obtained in previous studies that found more (Peters et al 2015, Pacheco-Yanes et al 2019, similar (Zhao et al 2019) or less (Elnaghy et al 2017) dentine preservation when using MaxWire instruments in comparison with conventional NiTi files. This may be so due to the different instruments that were used, especially with regard to cross section design and metallurgical properties.…”
Section: Discussionmentioning
confidence: 82%
See 2 more Smart Citations
“…Instruments with variable tapers may cause significantly less removal of coronal dentine in comparison with continuously tapered instruments whilst also providing adequate apical enlargement (Almeida et al 2019). Different results were obtained in previous studies that found more (Peters et al 2015, Pacheco-Yanes et al 2019, similar (Zhao et al 2019) or less (Elnaghy et al 2017) dentine preservation when using MaxWire instruments in comparison with conventional NiTi files. This may be so due to the different instruments that were used, especially with regard to cross section design and metallurgical properties.…”
Section: Discussionmentioning
confidence: 82%
“…2015, Pacheco‐Yanes et al . 2019), others reported greater removal of dentine (Elnaghy et al . 2017).…”
Section: Introductionmentioning
confidence: 97%
See 1 more Smart Citation
“…Ainda foram propostas técnicas de conformação que utilizam um instrumento, em movimento de rotação recíproca (AKSOY et al, 2019;BERUTTI et al, 2012;PACHECO-YANES et al, 2019;PLOTINO et al, 2012;VERSIANI et al, 2018;YARED, 2008YARED, , 2012, o qual se assemelha à movimentação feita pela instrumentação manual preconizada por Roane Sabala e Duncansom Jr. (1985).…”
Section: Introductionunclassified
“…No entanto, o grupo XPendo Shaper demonstrou maior centralização do preparo quando comparado ao grupo Reciproc Blue (p < 0,01). Não houve diferença estatística entre os grupos Reciproc Blue e Reciproc (p > 0,05) e a Reciproc e XP-endo Shaper (p > 0,05).A hipótese nula levantada de que os diferentes sistemas de instrumentos apresentam eficácia diferenciada no preparo de canais mesiais curvos de primeiros molares inferiores foi aceita, tendo em vista que o grupo XP-endo Shaper obteve resultados diferentes quando comparados aos demais grupos (Reciproc e Reciproc Blue).Diante da constante evolução dos materiais utilizados na Odontologia e, em especial, dos instrumentos endodônticos (ALRAHABI; ATTA, 2019;PACHECO- YANES et al, 2019;USLU et al, 2018;VERSIANI et al, 2018), é importante que a comunidade acadêmica e profissional esteja sempre atualizada quanto às principais características e desempenho desses dispositivos na clínica endodôntica. É sob esse contexto que este estudo foi elaborado, visando comparar o desempenho dos instrumentos Reciproc ® , Reciproc Blue ® e XP-Endo Shaper ® quando do PQM de canais mesiais curvos de primeiros molares inferiores.…”
unclassified