2015
DOI: 10.7454/mst.v19i2.3141
|View full text |Cite
|
Sign up to set email alerts
|

Transmission Electron Microscopy Characterization of High-Temperatur Oxidation of Fe-20Cr-5Al Alloy Prepared by Focused Ion Beam Technique

Abstract: The Focused Ion Beam (FIB) technique was applied for cross section preparation of the oxidized alloy for Transmission Electron Microscopy (TEM) study. Prior to preparation, the specimens of Fe-20Cr-5Al alloy sheet were oxidized in air at 1200 o C for 2 minutes, 10 minutes, 2 hours, and 100 hours. The microstructure and elemental composition of the samples were characterized using TEM equipped with an Energy Dispersive X-Ray Spectroscopy (EDX). The Electron Energy Loss Spectroscopy (EELS) was used to determine … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 5 publications
1
1
0
Order By: Relevance
“…In the ceramic membrane before the sintering furnace, the presence of asymmetric O-H stretching vibrations from Si-OH which is O-H stretching at the absorption peak of 3391.9 cm-1 with a wide band was identified. This is to the FTIR analysis conducted by Rumiyanti et al, 2021 [6] which states that the presence of a wave peak of 3421.7 cm-1 will indicate the asymmetric O-H stretching vibration of Si-OH. Another absorption peak such as at 2885 cm-1 represents the C-H group, To Mansur et al, 2008 the wave band with the interval 2840 and 3000 cm-1 refers to C-H stretching.…”
Section: Fourier Transform Infra-red Testing Results Of Silica-based ...supporting
confidence: 54%
See 1 more Smart Citation
“…In the ceramic membrane before the sintering furnace, the presence of asymmetric O-H stretching vibrations from Si-OH which is O-H stretching at the absorption peak of 3391.9 cm-1 with a wide band was identified. This is to the FTIR analysis conducted by Rumiyanti et al, 2021 [6] which states that the presence of a wave peak of 3421.7 cm-1 will indicate the asymmetric O-H stretching vibration of Si-OH. Another absorption peak such as at 2885 cm-1 represents the C-H group, To Mansur et al, 2008 the wave band with the interval 2840 and 3000 cm-1 refers to C-H stretching.…”
Section: Fourier Transform Infra-red Testing Results Of Silica-based ...supporting
confidence: 54%
“…TEM is one method that is widely agreed by scientists that ultrathin specimens of high quality are required for the investigation of almost all materials to the particle level [6]. Analysis using TEM has advantages such as being able to provide information about the composition of the sample with high resolution.…”
Section: Transmission Electron Microscopy (Tem) Testing From Silica B...mentioning
confidence: 99%