2015
DOI: 10.1016/j.protcy.2015.10.046
|View full text |Cite
|
Sign up to set email alerts
|

Transient Stability Enhancement by Optimal Location and Tuning of STATCOM Using PSO

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…The performance of STATCOM is implemented by applying a nonlinear time-domain simulation. The result shows that the optimal location and tuning of STATCOM has a great influence on the system transient stability enhancement [39].…”
Section: Enhancement Of Power System Transient Stability -A Reviewmentioning
confidence: 98%
See 1 more Smart Citation
“…The performance of STATCOM is implemented by applying a nonlinear time-domain simulation. The result shows that the optimal location and tuning of STATCOM has a great influence on the system transient stability enhancement [39].…”
Section: Enhancement Of Power System Transient Stability -A Reviewmentioning
confidence: 98%
“…The results obtained show that the application of STATCOM was more effective in damping than PSS [38]. Karthikeyan et al (2015) investigated transient stability improvement through optimal location and turning of STATCOM. The performance of STATCOM is implemented by applying a nonlinear time-domain simulation.…”
Section: Enhancement Of Power System Transient Stability -A Reviewmentioning
confidence: 99%
“…Flexible AC Transmission System (FACTS) devices have been contributing significantly in enhancing power system transient stability (low/high order oscillation) by regulating power flows and enhancing power transfer capacity of transmission system [1]- [3]. Among the multiple FACTS devices, the particular interest of this study is on static synchronous compensators (STATCOM) as this device improves power transfer capability [4], [5], enhances transient stability by regulating voltage [6], ameliorates inter-area oscillation [7] and provides faster and smoother voltage recovery through reactive power compensation [8]. In addition, STATCOM outperforms other FACTS devices in damping power system oscillations [9] and enhancing power transmission capacity in many occasions [10].…”
Section: Introductionmentioning
confidence: 99%
“…The fault clearing time (FCT) is set at random in a power system, hence, if the FCT is more than CCT, the system losses synchronism. A robust power system is largely determined by its response to disturbances; therefore, a high value of CCT indicates a robust power system [3]. The Nigerian 330-kV grid network is faced with series of challenges like voltage instability, long transmission lines, nature of transmission lines, high power losses [4], coupled with constant power demand increase and lack of sensitive equipment to detect and stabilize their challenges [5].…”
Section: Introductionmentioning
confidence: 99%