2018
DOI: 10.1109/access.2018.2828043
|View full text |Cite
|
Sign up to set email alerts
|

Transient Behavior Analysis of Offshore Wind Turbines During Lightning Strike to Multi-Blade

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 13 publications
0
10
0
Order By: Relevance
“…The calculation of the contact resistance between the grounding electrode and the soil needs to be completed with four steps: firstly, placing the grounding electrode in the test box and filling in different soils, then connecting the test circuit; secondly using the four-electrode method to measure the soil resistivity; thirdly the soil resistance R a2 and the contact resistance R 21 between the aluminum plate and the soil were equivalently calculated based on the finite element method; finally, the grounding electrode was used as the current injection electrode, and the single-sided aluminum plate was used as the current return electrode. The contact resistance R 22 of per unit area between the grounding electrode and the soil can be calculated from equation 3to (6). The contact resistance of per unit area of the grounding electrode under different soil conditions is shown in Table 3.…”
Section: ) Measurement Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The calculation of the contact resistance between the grounding electrode and the soil needs to be completed with four steps: firstly, placing the grounding electrode in the test box and filling in different soils, then connecting the test circuit; secondly using the four-electrode method to measure the soil resistivity; thirdly the soil resistance R a2 and the contact resistance R 21 between the aluminum plate and the soil were equivalently calculated based on the finite element method; finally, the grounding electrode was used as the current injection electrode, and the single-sided aluminum plate was used as the current return electrode. The contact resistance R 22 of per unit area between the grounding electrode and the soil can be calculated from equation 3to (6). The contact resistance of per unit area of the grounding electrode under different soil conditions is shown in Table 3.…”
Section: ) Measurement Methodsmentioning
confidence: 99%
“…(5) The conductive adhesive was used for coating the graphite evenly, tightly and integrally on the surface of the copper wire, which we call it graphite-coated copper wire. (6) Finally, the high current capability flexible graphite grounding material was woven with the graphite wire and graphite coated copper wire.…”
Section: Preparation Progress and Structurementioning
confidence: 99%
See 1 more Smart Citation
“…Hitherto, there is no related research that studies the impact of lightning strike to multi‐blade on lightning overvoltages and arresters configuration scheme on an offshore wind farm with multiple WTs. Although the transient overvoltages analysis of the lightning strike to multi‐blade in the offshore WT was carried out in [21], the influences of lightning strike to the multi‐blade on the transient overvoltages of the power cable and the arresters stresses of different WTs on offshore wind farm have not been taken into account.…”
Section: Introductionmentioning
confidence: 99%
“…Offshore wind power has developed rapidly in recent years [1], [2] due to characteristics such as high utilization hours and high-level, stable output [3]- [5]. Compared with onshore wind power, offshore wind power generations (OWPGs) are more susceptible to extreme weather [6], [7] (e.g., typhoons), causing wind power rampdown events [8] and seriously threatening the safety and stability of power system operation.…”
Section: Introductionmentioning
confidence: 99%