2013
DOI: 10.1016/j.enbuild.2012.11.001
|View full text |Cite
|
Sign up to set email alerts
|

Transient analysis based determination of derating factor for earth air tunnel heat exchanger in summer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(12 citation statements)
references
References 22 publications
0
9
0
Order By: Relevance
“…Several experimental and/or numerical studies on the EAHX cooling performances in hot climate, such as one of Marrakech (Morocco), have been performed through the world [9][10][11][14][15][16][17][18][19][20][21]. All of these studies concluded on the very interesting performances of the EAHX for air cooling, although these performances depend on many parameters, in particular the soil properties and the local climate.…”
Section: Experimental Projects and Guidelinesmentioning
confidence: 99%
See 1 more Smart Citation
“…Several experimental and/or numerical studies on the EAHX cooling performances in hot climate, such as one of Marrakech (Morocco), have been performed through the world [9][10][11][14][15][16][17][18][19][20][21]. All of these studies concluded on the very interesting performances of the EAHX for air cooling, although these performances depend on many parameters, in particular the soil properties and the local climate.…”
Section: Experimental Projects and Guidelinesmentioning
confidence: 99%
“…Most of these models are based on finite differences. Some of them are limited to the description of only one ""typical"" pipe [14,18,[28][29][30][31]. Others deal with several parallel running pipes, with or without possibility to treat more complicated cases than steady state flow rate, homogenous and laterally adiabatic soils, or sole sensible heat exchange [32][33][34][35].…”
Section: Modelsmentioning
confidence: 99%
“…However, heat and moisture transfer in shallow soil surrounding a heat exchanger is neither axi-symmetric normal to the pipe nor varying uniformly along the pipe for long term operation due to the influence of daily and seasonal climatic variations and interactions between soil and the heat exchanger. For more realistic simulation, therefore, numerical solution of a three-dimensional model is required and this type of numerical heat transfer model has been developed or applied by a number of researchers [17][18][19][20][21] to predict the performance of EAHXs. Both analytical and numerical models allow parametric analysis to be performed such as air and soil properties and pipe size but the numerical model would also enable additional parameters such as non-uniform soil properties and pipe configurations to be analysed.…”
Section: Introductionmentioning
confidence: 99%
“…Misra et al, (2013) conducted an exhaustive parametric analysis on the performance of earth air heat exchanger (EAHX) also analyzed how in continuous operation performance degrades and devised a term "derating factor" to relate this degradation. Their results show a variation of 0 % to 64 % in derating factor which is caused by choosing different parameters like air velocity, pipes dimensions, depth, soils thermal conductivity [6].…”
mentioning