2005
DOI: 10.1016/j.jms.2004.08.016
|View full text |Cite
|
Sign up to set email alerts
|

Transferring the high accuracy of the 10μm CO2 laser bands to far infrared region with internal calibration of CS2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
25
0

Year Published

2005
2005
2010
2010

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(29 citation statements)
references
References 17 publications
4
25
0
Order By: Relevance
“…The wavenumber precision in the region over 200 cm À1 would have been degraded by the calibration. On the other hand, the accuracy given for the D 2 CO lines in [2] is in the same order as the absolute accuracy of the new water lines [6]. The other advantage of these water lines is that they are lying in the upper region of the measured spectrum.…”
Section: Methodsmentioning
confidence: 70%
See 1 more Smart Citation
“…The wavenumber precision in the region over 200 cm À1 would have been degraded by the calibration. On the other hand, the accuracy given for the D 2 CO lines in [2] is in the same order as the absolute accuracy of the new water lines [6]. The other advantage of these water lines is that they are lying in the upper region of the measured spectrum.…”
Section: Methodsmentioning
confidence: 70%
“…It has a form Dk = Dm ref /m cal + Dk std , where Dm ref = 30 · 10 À6 cm À1 is the mean accuracy of the lines in the calibration source [6], m cal is the average position of calibration lines in the present measurement, and Dk std = 1.234 · 10 À7 is the 1) is the uncertainty to determine the line position in the spectrum. According to this the accuracy of the used lines is varying from 20 to 170 · 10 À6 cm À1 .…”
Section: Methodsmentioning
confidence: 99%
“…This beamline has enjoyed a very productive history over the past 15 years [11][12][13][14][15][16][17][27][28][29][30][31][32][33][34][35][36][37][38][39][40][41][42][43][44] , achieving a remarkable standard deviation of just 0.00010 cm À1 for some 1900 fitted transitions. The first figure of this paper is reproduced here as Fig.…”
Section: Max-labmentioning
confidence: 99%
“…1. Propyne continued as the subject of further papers based on MAX-lab spectra [17,31,44], and the excellent wavenumber precision which was possible in the far-IR region was utilized, together with non-SR results from other labs, to establish improved wavenumber standards based on CO 2 ,C S 2 , and H 2 O [35,36].…”
Section: Max-labmentioning
confidence: 99%
“…Recently, the high accuracy of the carbon dioxide (CO 2 ) laser bands around 10 lm [1] was transferred to the far infrared region from 230 to 480 cm À1 with the rotation vibration bands of carbon disulfide ( 12 CS 2 ) [2]. The bands 3m 2 and m 1 + m 2 were compared to laser lines.…”
Section: Introductionmentioning
confidence: 99%