Transesophageal Echocardiography in Critically Ill Acute Postoperative Infants: Comparison of AcuNav Intracardiac Echocardiographic and microTEE Miniaturized Transducers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
14
0
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 33 publications
1
14
0
1
Order By: Relevance
“…Some studies have assessed the efficiency of micro-TOE during perioperative care for patients undergoing cardiac surgery using different miniaturized probes [10,13,15,22]. We provide further evidence of the impact of TOE for children undergoing cardiac catheterization.…”
Section: Discussionmentioning
confidence: 94%
See 2 more Smart Citations
“…Some studies have assessed the efficiency of micro-TOE during perioperative care for patients undergoing cardiac surgery using different miniaturized probes [10,13,15,22]. We provide further evidence of the impact of TOE for children undergoing cardiac catheterization.…”
Section: Discussionmentioning
confidence: 94%
“…The new micro-multiplane TOE probe was designed to overcome these former issues. However, few reports are available that have assessed the safety and efficiency of the new release of the micro-multiplane TOE probe S8-3t [10,15].…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…This probe provided good quality images in very small infants [ 15 ]. Additionally, it could be demonstrated that the intraoperative and postoperative use of the microTEE probe provides adequate accuracy albeit inferior image quality when compared with the paediatric multiplane TEE probe in infants [ 7 , 16 ]. An alternative to the microTEE might be the disposable ClariTEE catheter (Imacor, Inc., New York, USA).…”
Section: Discussionmentioning
confidence: 99%
“…Les communications interventriculaires quel qu'en soit le type sont aussi parfaitement décrites par la 3D, optimisant la prédiction de fermeture spontanée ou guidant les autres au choix de la technique de fermeture (cathétérisme ou chirurgie). Si la voie trans-thoracique est la plus utilisée chez l'enfant, les sondes trans-oesophagiennes sont désormais 3D et très récemment sont apparues des sondes 2D microscopiques pouvant être introduite chez le nouveau-né (taille d'une sonde gastrique les rendant beaucoup plus maniables au bloc et en réanimation) [16].…”
Section: L'échocardiographie 3dunclassified