1999
DOI: 10.1111/j.1600-0846.1999.tb00119.x
|View full text |Cite
|
Sign up to set email alerts
|

Transepidermal water loss kinetic modeling approach for the parameterization of skin water dynamics

Abstract: Background/aims: The evaluation of transepidermal water loss (TEWL) is one of the methods most frequently used in studies involving skin water dynamics. However, TEWL does not provide a direct measurement of epidermal barrier function, being rather a surrogate effect of it. In particular, when external stimuli change cutaneous water balance, these stimuli must be taken into account in order to achieve a rigorous interpretation of the results. Since TEWL is primarily attributed to the water flux from the deepe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
43
0
5

Year Published

2002
2002
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(49 citation statements)
references
References 16 publications
1
43
0
5
Order By: Relevance
“…A fim de melhorar a precisão das medições da PTEA, outras abordagens dinâmicas têm sido sugeridas. Os testes de acumulação de humidade (MAT) [9] , de sorção/dessorção [10] e de oclusão plástica (POST) [11] são exemplos relevantes que servem como base conceptual para o modelo aqui aplicado, permitindo uma descrição quantitativa mais precisa do balanço de massa de água cutânea ao longo do tempo [12][13][14] . O presente estudo avalia o impacto da utilização de um gel desinfetante de base alcoólica sobre a função de 'barreira' epidérmica, usando uma abordagem de modelação cinética das curvas de dessorção da PTEA após um POST.…”
Section: Methodsunclassified
See 2 more Smart Citations
“…A fim de melhorar a precisão das medições da PTEA, outras abordagens dinâmicas têm sido sugeridas. Os testes de acumulação de humidade (MAT) [9] , de sorção/dessorção [10] e de oclusão plástica (POST) [11] são exemplos relevantes que servem como base conceptual para o modelo aqui aplicado, permitindo uma descrição quantitativa mais precisa do balanço de massa de água cutânea ao longo do tempo [12][13][14] . O presente estudo avalia o impacto da utilização de um gel desinfetante de base alcoólica sobre a função de 'barreira' epidérmica, usando uma abordagem de modelação cinética das curvas de dessorção da PTEA após um POST.…”
Section: Methodsunclassified
“…TEWL was continuously measured for 30 minutes, at a frequency of 0.1 Hz (one measurement every ten seconds) and modelled by a bicompartment model. This model, first proposed in 1999 [12] , considers the barrier and inner layers of the skin as two different water compartments. The first compartment is the skin barrier with low water content, while the second represents the innermost layers of the skin with higher water levels.…”
Section: Materiais E Métodosmentioning
confidence: 99%
See 1 more Smart Citation
“…A PTEA, expressa em (g/m 2 / h) foi medida com um aparelho Tewameter TM300 (Courage + Khazaka Electronics GmbH, Colónia, Alemanha); hidratação epidérmica superficial (HS) expressa em unidades arbitrárias (UA), utilizando o dispositivo MoistureMeter-SC® (Delfin Technologies Ltd, Kuopio, Finlândia) e hidratação epidérmica profunda (HP), expressa em unidades arbitrá-rias (UA), utilizando o dispositivo MoistureMeter-D® (Delfin Technologies, Finlândia). As curvas de dessorção da PTEA foram ajustadas a um modelo cinético bi--compartimental já descrito [13][14][15] , utilizando o software MatLab (Toolbox MATLAB e Estatística Versão 2011, The MathWorks, Inc., Natick, Massachusetts, EUA), de onde foram extraídos dois parâmetros cinéticos: t 1/2 evap (tempo de meia-vida de evaporação) e DWM (massa de água dinâmica). A evolução dos valores absolutos da PTEA e dos parâmetros cinéticos derivados das curvas foi comparada para ambas as mãos e entre as mãos controlo e teste pelo teste teste não paramétrico de Wilcoxon para amostras emparelhadas (p<0.05).…”
Section: Materiais E Métodosunclassified
“…TEWL, expressed in (g/m 2 /h) was measured with a Tewameter TM300 (Courage + Khazaka Electronics GmbH, Cologne, Germany); superficial epidermal hydration (SH) expressed in arbitrary units (AU), using the MoistureMeter-SC ® device (Delfin Technologies Ltd, Kuopio, Finland); and deep epidermal hydration (DH) expressed in arbitrary units (AU), using the MoistureMeter-D ® device (Delfin Technologies, Finland). The TEWL desorption curves were fitted to a bi-compartment kinetic model previously described [13][14][15] , using MatLab software (MATLAB and Statistics Toolbox Release 2011, The MathWorks, Inc., Natick, Massachusetts, USA), from which two kinetical parameters were extracted: t 1/2 evap (half-life of evaporation) and DWM (dynamic water mass). The evolution of the absolute TEWL values and of curve-derived kinetic parameters were determined in each hand and between control and test hands by the Wilcoxon signed-rank test (IBM SPSS Statistics for Windows, 20.0 version, Armonk, NY: IBM Corp).…”
Section: Materiais E Métodosmentioning
confidence: 99%