2019
DOI: 10.1007/978-1-4939-9841-8_9
|View full text |Cite
|
Sign up to set email alerts
|

Transcutaneous Measurement of Glomerular Filtration Rate in Rodents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…The measurement was performed for at least 2 hours, during which the animal was completely awake and freely moving. Half-life excretion of the administered ABZWCY-HPβCD was calculated based on a 3-compartment model using the open source freely-available software ‘GFR measure’ ( https://www.mathworks.com/products/compiler/matlab-runtime.html ) ( 28 ).…”
Section: Methodsmentioning
confidence: 99%
“…The measurement was performed for at least 2 hours, during which the animal was completely awake and freely moving. Half-life excretion of the administered ABZWCY-HPβCD was calculated based on a 3-compartment model using the open source freely-available software ‘GFR measure’ ( https://www.mathworks.com/products/compiler/matlab-runtime.html ) ( 28 ).…”
Section: Methodsmentioning
confidence: 99%
“…The NIC-Kidney device (Mannheim Pharma & Diagnostics GmbH, Mannheim, Germany) was attached to the shaved back of each animal. After a few minutes for collection of baseline values, fluorescein isothiocyanate–labeled sinistrin (7.5 mg/100 g) was injected via the tail vein, and tGFR was calculated based on the kinetics of fluorescence decay ( 33 , 34 ).…”
Section: Methodsmentioning
confidence: 99%
“…The ABZWCY-HPβCD and AAZWCY-HPβCD fluorescent probes absorb at around 704 nm and emit at around 790 nm in plasma, with a Stoke's shift of roughly 86 nm. This allows deeper tissue penetration and easier transcutaneous measurement [2,26]. Similarly, Cy7.5 dye is used to label carboxymethyl inulin (CMI) to image the NIR-GFR marker using a transcutaneous pulse dye densitometer (TPDD) [27].…”
Section: Gfr Markersmentioning
confidence: 99%
“…The data from the device is recorded for a baseline (without dye) after which FITC-S is injected intravenously. A modified version of this device has been developed using NIR LEDs, which uses ABZWCY-HPβCD that has an emission maximum at 790 nm [26].…”
Section: Non-invasive Measurement Techniquesmentioning
confidence: 99%
See 1 more Smart Citation