1997
DOI: 10.1016/s0009-9120(96)00131-2
|View full text |Cite
|
Sign up to set email alerts
|

Transcutaneous bilirubinometry: Its role in the assessment of neonatal jaundice

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
35
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(35 citation statements)
references
References 53 publications
0
35
0
Order By: Relevance
“…Other studies have generally demonstrated that the JM meter readings are less accurate in babies with dark skin. 7 There are several applications for the TCB measurements. One is in a jaundiced infant to determine if serum bilirubin should be drawn to guide treatment.…”
Section: Discussionmentioning
confidence: 99%
“…Other studies have generally demonstrated that the JM meter readings are less accurate in babies with dark skin. 7 There are several applications for the TCB measurements. One is in a jaundiced infant to determine if serum bilirubin should be drawn to guide treatment.…”
Section: Discussionmentioning
confidence: 99%
“…A noninvasive alternative to visual inspection is the use of instruments that measure bilirubin transcutaneously (8 -20 ). Transcutaneous bilirubin (TcB) 3 concentrations correlate with laboratory measurement, but they may underestimate the serum bilirubin, particularly when concentrations are Ͼ171 mol/L (13,14 ). Despite this shortcoming, the use of TcB to screen newborns for hyperbilirubinemia has been suggested as a fast, reasonable alternative to laboratory-based bilirubin testing (8 -10, 13, 14, 18 ).…”
Section: Evidence-based Laboratory Medicine and Test Utilizationmentioning
confidence: 99%
“…Thirty-two separate studies in infants from different population groups concluded that transcutaneous readings are correlated with plasma bilirubin. 40 The equation relating the two is population and bilirubin method dependent. For meters such as the Minolta Airshields JM102, the regression equation must be established by each centre for its own population and bilirubin methodology.…”
Section: First-line Assessment Of Jaundice Transcutaneous Monitorsmentioning
confidence: 99%
“…41 Precision studies for transcutaneous monitors used cuvettes containing bilirubin solutions, or a small number of repeat measurements on an infant over a short timeperiod. 40 The reported studies have generally been carried out as part of a research protocol on a limited number of subjects. It is possible that the CIs of the correlation with plasma bilirubin could be even wider in routine practice.…”
Section: First-line Assessment Of Jaundice Transcutaneous Monitorsmentioning
confidence: 99%