2018
DOI: 10.1016/j.pcad.2018.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Transcatheter Valve Replacement for Right-sided Valve Disease in Congenital Heart Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 127 publications
0
10
0
Order By: Relevance
“…41 Most pediatric surgeons recommend bioprosthetic valves in the tricuspid and pulmonary positions and mechanical valves in the mitral position and either a mechanical valve or, less commonly, an autograft valve in the aortic position (Ross procedure). 12,41,54,55 Nevertheless, some patients have a contraindication to anticoagulation or a predilection for thrombus formation or prefer to avoid anticoagulation and also may receive bioprosthetic valves on the left side. Recently, some families are even requesting bioprosthetic AoV so that their child subsequently can receive a valve-invalve (ViV) TAVR rather than a reoperative valve replacement.…”
Section: Tricuspid Valve Diseasementioning
confidence: 99%
See 4 more Smart Citations
“…41 Most pediatric surgeons recommend bioprosthetic valves in the tricuspid and pulmonary positions and mechanical valves in the mitral position and either a mechanical valve or, less commonly, an autograft valve in the aortic position (Ross procedure). 12,41,54,55 Nevertheless, some patients have a contraindication to anticoagulation or a predilection for thrombus formation or prefer to avoid anticoagulation and also may receive bioprosthetic valves on the left side. Recently, some families are even requesting bioprosthetic AoV so that their child subsequently can receive a valve-invalve (ViV) TAVR rather than a reoperative valve replacement.…”
Section: Tricuspid Valve Diseasementioning
confidence: 99%
“…Results using the Harmony valve (Medtronic, Minneapolis, MN) in the United States are encouraging, although a limited number of valve sizes are available, thus excluding a large number of patients. 8,55 In addition, the Alterra Adaptive Pre-Stent (Edwards Lifesciences, Irvine, CA) is in clinical trials and was designed to remodel the native RVOT internally so that a Sapien S3 subsequently can be implanted in the neo-RVOT. 55 Ultimately, the hope is that transcatheter PVR technology will offer a significantly lower risk option than reoperative surgery for patients requiring PVR regardless of their original anatomy.…”
Section: Transcatheter Pulmonic Valve Replacementmentioning
confidence: 99%
See 3 more Smart Citations