Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
62
0
12

Year Published

1997
1997
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 107 publications
(78 citation statements)
references
References 10 publications
4
62
0
12
Order By: Relevance
“…Some studies found that the coil migration rate with this method was 8-16%. [10][11][12] More recently, detachable coils, with a long-term completeocclusion rate of 98-100%, 11,13 have become available. The special characteristic of these coils is controlled release: when the guidewire is screwed, the coil finally leaves the guidewire and so the coil migration rate is only 1.4-8%.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some studies found that the coil migration rate with this method was 8-16%. [10][11][12] More recently, detachable coils, with a long-term completeocclusion rate of 98-100%, 11,13 have become available. The special characteristic of these coils is controlled release: when the guidewire is screwed, the coil finally leaves the guidewire and so the coil migration rate is only 1.4-8%.…”
Section: Discussionmentioning
confidence: 99%
“…The special characteristic of these coils is controlled release: when the guidewire is screwed, the coil finally leaves the guidewire and so the coil migration rate is only 1.4-8%. 11,13 There are a few recent reports of percutaneous coil embolization for adult PDA. Two of the 3 adult patients in the present study had symptoms of heart failure due to a relatively large PDA, a situation often experienced in adult patients with PDA.…”
Section: Discussionmentioning
confidence: 99%
“…Literatüre bakıldığında cihaz seçiminde ana kriter PDA'nın çap ve morfolojisidir. Genel olarak önerilen, maliyetin de hesaba katılmasıyla, ince duktuslarda koillerin, geniş duktuslarda ise tıkaç özelliği olan cihazların kullanılmasıdır (32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42)(43)(44)(45)(46)(47)(48).…”
Section: Ayrıcı Tanıunclassified
“…Koil yerleştirme işlemleri daha önce yayımlanan araştırmalarda tanımlandığı gibi yapıldı (11)(12)(13)(14). Yerleştirilecek koil'in çapı PDA'nın en dar çapının en az 1.7 katı olacak şekilde belirlendi.…”
Section: Introductionunclassified